# Cantabile EEBUS
|
|
|
|
The add-on speaks EEBUS with the devices in your home: the grid
|
|
operator's control box (§14a EnWG), heat pumps (Vaillant, Viessmann,
|
|
Bosch and others), wallboxes and inverters. It shows them in Home
|
|
Assistant under Cantabile's names and units, so the Cantabile agent maps
|
|
them exactly, and it hands the grid operator's limit to the agent.
|
|
|
|
## Your consent
|
|
|
|
In the add-on's configuration, **Cantabile may control devices** is your
|
|
consent (the same text as Cantabile's other add-ons and the Cantabile
|
|
Hub's setup). Without it the add-on pairs and reads your devices, shows
|
|
them in Home Assistant and tells the Cantabile agent about the grid
|
|
operator's limit, but writes nothing to them: no command, and not the
|
|
grid operator's limit either. The page says so at the top. You can give
|
|
or take back the consent there at any time; the add-on restarts with it
|
|
and records when.
|
|
|
|
The add-on sends nothing out of your home: its values go to Home
|
|
Assistant, the grid operator's limit to the Cantabile agent on the same
|
|
Home Assistant (which shares data with Cantabile only with your consent
|
|
in its own configuration).
|
|
|
|
## Pairing
|
|
|
|
EEBUS devices trust each other by their SKI (a fingerprint of the
|
|
device's certificate). Open the add-on's page (Cantabile EEBUS):
|
|
|
|
1. Switch EEBUS on in the device's app or menu (for example the
|
|
myVAILLANT or ViCare app, or the wallbox's web page). The device
|
|
appears under **Found on the network**, or asks to be paired.
|
|
2. Compare the SKI on the page with the one the device shows (its app,
|
|
display or label; for the control box, the installer or the grid
|
|
operator gives it).
|
|
3. **Pair**. In the device's app, trust "Cantabile EEBUS bridge" if it
|
|
asks. The page shows the bridge's own two SKIs at the bottom: one for
|
|
heat pumps, wallboxes and inverters, one for the grid operator's
|
|
control box (give that one to the installer).
|
|
|
|
Each device is paired once; the add-on keeps its own certificate in its
|
|
data, so the pairing survives updates. A device's page opens with a link
|
|
`#<device>` (from Cantabile's dashboard).
|
|
|
|
## The grid operator's limit (§14a)
|
|
|
|
A paired control box is **sealed**: nothing in Home Assistant or Cantabile
|
|
lifts its limit, and it can't be unpaired on the page (only the grid
|
|
operator, through Cantabile). While it limits the home, the add-on passes
|
|
the limit on to the heat pumps and wallboxes at once and the Cantabile
|
|
agent plans within it. Without the control box's heartbeat for two
|
|
minutes the failsafe limit holds for its failsafe time: the control box's
|
|
own values; until it sent them §14a's minimum of 4.2 kW (BNetzA
|
|
BK6-22-300) for the shortest time the EEBUS use case allows (2 hours).
|
|
|
|
Toward the control box the add-on declares the controllable devices'
|
|
nominal power: what the heat pumps and wallboxes report (a heat pump's
|
|
nominal power, a wallbox's maximum current and phases), else the rating
|
|
you enter on a device's page (from its nameplate). It never declares a
|
|
guess: while any heat pump or wallbox has no known power, or none is
|
|
paired, nothing is declared and the add-on does not offer the grid
|
|
operator's use case (LPC); the page's grid card says why ("nominal power
|
|
unknown: enter the controllable devices' ratings") and which device needs
|
|
a rating. When a limit ends, a wallbox goes back to its own maximum
|
|
current, else to the current it had before; if neither is known it stays
|
|
and the page says so. While its power is not known, a device's share of a
|
|
limit is an equal one (the sum never exceeds the limit), and a W budget is
|
|
turned into amps as if on three phases (never more than the budget).
|
|
|
|
## Protection
|
|
|
|
Every control of a heat pump or wallbox starts **protected**: Cantabile
|
|
never sets a heat pump to 0 W or a wallbox to 0 A. Only you lift a
|
|
protection, on the add-on's page, one control at a time; every change is
|
|
logged with who and when.
|
|
|
|
## Options
|
|
|
|
- **Cantabile may control devices**: your consent, above (off until you
|
|
give it).
|
|
- **Simulate**: a simulated control box, heat pump and wallbox, with
|
|
buttons on the page to send a limit or lose the heartbeat.
|
|
- **Read only**: commands are checked and logged, never written.
|
|
- **Pass on the grid operator's limit**: on by default.
|
|
|
|
The add-on uses the host's network: EEBUS devices find it by mDNS and
|
|
connect to TCP ports 4712 (the control box) and 4713 (the other
|
|
devices). The devices' support differs by model and
|
|
firmware; the profiles are untested on real hardware so far.
|
|
|
|
Open-source components and their licences: see
|
|
`/usr/share/doc/cantabile-eebus/THIRD-PARTY-NOTICES.md` in the image.
|
|
|
|
---
|
|
|
|
© 2026 Setti Solutions S.R.L, [www.setti.md](https://www.setti.md). All rights reserved.
|