@@ -1,5 +1,15 @@
|
||||
# Changelog
|
||||
|
||||
## Unreleased
|
||||
|
||||
- Declares to the grid operator's control box only what is known: the
|
||||
heat pumps' and wallboxes' reported power, else the rating you enter on
|
||||
a device's page. Unknown: nothing is declared and the grid operator's
|
||||
use case (LPC) is not offered; the page says why. No more 32 kW, 6 kW per
|
||||
heat pump or 16 A x 3 per wallbox stood in for an unknown power.
|
||||
- The failsafe limit and time are the control box's own; until it sent
|
||||
them §14a's 4.2 kW for the use case's shortest 2 hours.
|
||||
|
||||