1.7 KiB
1.7 KiB
Changelog
Unreleased
- Declares to the grid operator's control box only what is known: the heat pumps' and wallboxes' reported power, else the rating you enter on a device's page. Unknown: nothing is declared and the grid operator's use case (LPC) is not offered; the page says why. No more 32 kW, 6 kW per heat pump or 16 A x 3 per wallbox stood in for an unknown power.
- The failsafe limit and time are the control box's own; until it sent them §14a's 4.2 kW for the use case's shortest 2 hours.
0.1.x
- First version (experimental, not yet tried with real devices): pairs with EEBUS devices on your network on the add-on's page, after you compare their SKI: the grid operator's control box (§14a), heat pumps (Vaillant aroTHERM, Viessmann Vitocal, Bosch Compress and others), wallboxes and inverters.
- Shows each paired device in Home Assistant in the area "Cantabile": power and energy (kWh), the heat pump's power limit, the wallbox's car, charging power, energy and current limit, an inverter's solar and battery, the grid connection point.
- The grid operator's limit: shown on the page, passed on to the heat pumps and wallboxes at once and handed to the Cantabile agent, which plans within it. It can't be lifted from Home Assistant.
- Every control starts protected: Cantabile never sets a heat pump to 0 W or a wallbox to 0 A unless you lift that on the page.
- Your consent to control in the add-on's configuration; without it the add-on only reads.
- A simulator (option "Simulate") with a control box, a heat pump and a wallbox to try it without devices.
- The page in English or German, light or dark as Home Assistant.
© 2026 Setti Solutions S.R.L, www.setti.md. All rights reserved.