# Changelog
## Unreleased
- Declares to the grid operator's control box only what is known: the
heat pumps' and wallboxes' reported power, else the rating you enter on
a device's page. Unknown: nothing is declared and the grid operator's
use case (LPC) is not offered; the page says why. No more 32 kW, 6 kW per
heat pump or 16 A x 3 per wallbox stood in for an unknown power.
- The failsafe limit and time are the control box's own; until it sent
them §14a's 4.2 kW for the use case's shortest 2 hours.
## 0.1.x
- First version (experimental, not yet tried with real devices): pairs
+17 -2
View File
@@ -49,8 +49,23 @@ lifts its limit, and it can't be unpaired on the page (only the grid
operator, through Cantabile). While it limits the home, the add-on passes
the limit on to the heat pumps and wallboxes at once and the Cantabile
agent plans within it. Without the control box's heartbeat for two
minutes the failsafe limit holds (4.2 kW unless the control box set
another) for its failsafe time.
minutes the failsafe limit holds for its failsafe time: the control box's
own values; until it sent them §14a's minimum of 4.2 kW (BNetzA
BK6-22-300) for the shortest time the EEBUS use case allows (2 hours).
Toward the control box the add-on declares the controllable devices'
nominal power: what the heat pumps and wallboxes report (a heat pump's
nominal power, a wallbox's maximum current and phases), else the rating
you enter on a device's page (from its nameplate). It never declares a
guess: while any heat pump or wallbox has no known power, or none is
paired, nothing is declared and the add-on does not offer the grid
operator's use case (LPC); the page's grid card says why ("nominal power
unknown: enter the controllable devices' ratings") and which device needs
a rating. When a limit ends, a wallbox goes back to its own maximum
current, else to the current it had before; if neither is known it stays
and the page says so. While its power is not known, a device's share of a
limit is an equal one (the sum never exceeds the limit), and a W budget is
turned into amps as if on three phases (never more than the budget).
## Protection
+1 -1
View File
@@ -4,7 +4,7 @@
# Assistant that isn't a Cantabile Hub. Devices are paired on its page
# (ingress), by their SKI.
name: Cantabile EEBUS
version: "0.1.676"
version: "0.1.901"
slug: cantabile_eebus
description: Pairs with EEBUS devices (the grid operator's control box, heat pumps, wallboxes, inverters), shows them in Home Assistant under Cantabile's names and hands the grid operator's §14a limit to the Cantabile agent; every control with its protection.
url: https://cantabile.cloud
Binary file not shown.

Before

Width:  |  Height:  |  Size: 12 KiB

After

Width:  |  Height:  |  Size: 8.2 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 15 KiB

After

Width:  |  Height:  |  Size: 14 KiB