# Copyright © 2026 Setti Solutions S.R.L, www.setti.md. All rights reserved.
|
||
"""The plan: a MILP over the next 48 h in 15-minute steps (HiGHS), re-made
|
||
every 15 minutes in a subprocess with a time limit (controller.py):
|
||
|
||
python -m cantabile_edge.optimizer < state.json > plan.json
|
||
|
||
Objective: the grid's cost (the tariff's import and export prices) plus
|
||
penalties for comfort the plan gives up and for the floors and limits it
|
||
would cross.
|
||
|
||
Prices (docs/parameters.md U1; no price is ever made up):
|
||
- no tariff (none received, expired, none for now: state["prices"]
|
||
status "none"): the plan is made without prices, for comfort, the
|
||
limits and the owner's musts only. The meter's energy and the devices'
|
||
energy carry a tiny engineering weight (NO_PRICE_EUR_KWH: of plans
|
||
otherwise equal, the one that moves the least energy), so nothing is
|
||
shifted, pre-heated, stored or exported for a price; the battery stays
|
||
in its own mode unless a reserve the owner set needs charging; the
|
||
market's contracts are not planned (nothing to compare them with).
|
||
The plan's cost and baseline are None and its price_note says why.
|
||
- a tariff that prices only the first n steps (beyond its end, or a gap):
|
||
the plan covers those n steps only (_cut), never a step without a
|
||
price as if it were free.
|
||
- a step without an export price: export is unpriced there, it carries
|
||
no value (neither earned nor charged, coefficient 0) - not "0 ct" as a
|
||
fact: the plan exports what it cannot use, but never discharges a
|
||
battery or plans anything to export, and the meter's import/export
|
||
switch treats it as worth nothing. Curtailing (spill) has its own small
|
||
engineering cost (SPILL_EUR_KWH), so PV is never curtailed while the
|
||
meter can take it, whatever export is worth; a negative export price
|
||
(a real one) still curtails. Floors and limits are soft here, with a penalty far above any
|
||
price, so there is always a plan (a room already below its floor must be
|
||
able to come back); the executor's guard enforces them hard on every action.
|
||
|
||
Device models (one function each, small and replaceable):
|
||
battery state of charge (estimated from params.soc_pct when no sensor),
|
||
charge/discharge power, efficiency, never both at once (binary);
|
||
the last charge free within its bounds, each kWh left worth V
|
||
(end_value: the Parameters page's battery.end_value_pct of the
|
||
mean feed-in price, under the cheapest import price; missing:
|
||
0, noted in the plan's "notes"); its idle loss (S.2): the
|
||
standby W taken from the cells while they hold charge (the grid
|
||
only as a valve), the cells' self-discharge as a factor per step
|
||
dhw_tank a hot-water tank's stored heat above the cold water (one node,
|
||
S.5): its standing loss UA (T - T_room), its heater's heat by
|
||
carrier, the hot water drawn (the dhw forecast), comfort between
|
||
min and max temperature, a legionella run where planned; the
|
||
plan's "storage" reports what each store loses
|
||
heating a room's first-order thermal model (R in K/kW, C in kWh/K, the
|
||
cooling outside temperature, heat from the device, from the sun
|
||
through the room's covers, and the fit's internal gain and sun
|
||
(internal_gain_w, solar_m2 x the irradiance; the sun's only
|
||
where the room has no cover in the plan, which carries it));
|
||
comfort target when occupied, setback/setup otherwise; a
|
||
switched boiler is on/off (binary). Only with its R and C (the
|
||
mapping's both, or a fit: never built-in defaults), its electric
|
||
power (max_power_w), its COP where the model needs it and its
|
||
temperature now; else the room is not planned (inputs.
|
||
room_refusal): its thermostat follows the owner's
|
||
or installer's schedule within the room's limits
|
||
(fallback_entries), else keeps its own setpoint
|
||
ev the energy needed by the departure time, between min and max
|
||
current (binary), only while connected
|
||
cover the share of the sun's heat into its room (0 closed .. 1 open);
|
||
a small penalty for closing it while someone is home in daylight.
|
||
With a schedule (shades.py: rules on the sun on its facade, the
|
||
season, quiet hours) its positions are fixed to it and its plan
|
||
entries are the schedule's moves
|
||
|
||
Heat by its source (docs/methods.md E6; params.heat_source, the prices
|
||
state["price_gas"] and state["price_heat"] per step, fleet heatprice.go):
|
||
electric / heat_pump electric W through the meter at the import price; heat
|
||
= COP x W (params cop, or cop_curve at the step's
|
||
outside temperature)
|
||
boiler gas W (billed, Hs) at the gas price; heat = the
|
||
boiler's efficiency x W; up to max_heat_w of heat
|
||
district heat W at the heat price; up to max_heat_w
|
||
hybrid both, one at a time (a binary per step: the heat pump
|
||
or the boiler), each change of source costing the
|
||
Parameters page's heat.hybrid_switch_eur (state
|
||
"params", from the tariff bundle: no flapping)
|
||
The plan's cost then counts gas and heat too (gas_eur, heat_eur). A control
|
||
whose price or facts are missing never reaches the plan (inputs.py
|
||
heating_refusal: refused with the reason). A boiler's gas follows its
|
||
part-load curve (E6.4: the mapping's boiler_type or part_load_curve; LP
|
||
segments where convex, binaries where not); a source's heat and its cost
|
||
are HeatSupply's, the heat no model decides (the space heat where no room
|
||
is planned, the hot water drawn) heat_demand's: the heat outlook (A2.16), a
|
||
fixed labelled term of the cost (cost_parts.heat_outlook_eur). CO2 (A2.15):
|
||
the Parameters page's co2.planner_eur_per_t on the grid import, gas and
|
||
district heat at the tariff bundle's factors; the plan reports co2_kg.
|
||
|
||
The grid operator's limit (gridorder.py, state["grid_order"]: §14a through
|
||
the EEBUS bridge): the controllable consumers may draw at most
|
||
limit_w from the grid beyond the household's own net load, i.e. the import
|
||
at most max(0, load - pv) + limit_w per step, with a penalty far above any
|
||
building request (nobody overrides it).
|
||
|
||
The market's contracts in force (state["market"], from the market bundle;
|
||
the market's step 2, minimal, shadow: the plan only, no commands): a contract
|
||
the home buys on is an import source at its price, one it sells on an
|
||
export sink, through the same meter as the grid (which keeps the tariff's
|
||
import and feed-in prices), so the plan exchanges where the contract beats
|
||
the grid. Each step uses its own slot's terms (window, amounts, price) when
|
||
the bundle carries the coming slots (a contract's "terms", term_at). The
|
||
plan's "market" lists per contract the planned kWh and the saving against
|
||
the grid (vs_grid_eur).
|
||
|
||
The building's requests (building.py, state["building"]): a load limit on
|
||
the grid import and a thermostat cap are constraints with a penalty (binding
|
||
far above any price, flexible with a price), a shift request a soft target
|
||
(the window's import lowered by its kWh against the house's own net load).
|
||
A battery plan (the building's one plan for its battery, its own box
|
||
following it) is a tracking target per step: the batteries' grid-side power
|
||
(their sum) at the building's W, each kWh off it at the request's penalty
|
||
(above any price, below the owner's floors and the SoC bounds, which win:
|
||
battery_plan). The battery's plan entries then say "building <id>: ..." and
|
||
stay setpoints (not the inverter's own self-consumption mode). A battery
|
||
bound to a building (building.py battery_bound) charges beyond the
|
||
building's W only from the PV surplus, and where no plan covers a step
|
||
(lapsed, or beyond its 24 h) it is in self-consumption only: no grid
|
||
charging, no discharge into the grid, the inverter's own mode.
|
||
|
||
The owner's preferences (preferences.py, a device's "pref"): a room's
|
||
target per step from its schedule (in place of the occupied hours) at the
|
||
comfort cost, and a "must" as a floor (heating) or limit (cooling) with the
|
||
penalty MUST_EUR_K, inside the bounds and under a building's thermostat cap; a
|
||
car's ready-by time and energy (a must at EV_MUST_EUR_KWH, a prefer valued
|
||
at its max_ct per kWh with min_kwh at EV_SHORT_EUR_KWH); a battery's
|
||
reserve as its floor per step. The plan's "prefs" says per preference
|
||
whether it is met; with state["prefs_cost"] its "prefs_cost" the cost of
|
||
each must (pref_costs: the plan made again without it).
|
||
"""
|
||
import copy
|
||
import json
|
||
import math
|
||
import sys
|
||
import time
|
||
from datetime import datetime, timedelta, timezone
|
||
from zoneinfo import ZoneInfo
|
||
|
||
import highspy
|
||
from highspy.highs import highs_linear_expression as Lin
|
||
|
||
from .controls import ERP_TEST_DT_K, HOURS_PER_MONTH, cop_at, ev_volts, gas_segments, part_load, relative_efficiency
|
||
from . import battery_core
|
||
from .evphases import words as phase_words
|
||
from .storefit import WATER_WH_PER_L_K
|
||
from .plansplit import saving_parts
|
||
|
||
PENALTY_LIMIT = 5.0 # EUR per unit and step across a floor or limit (K, % of a battery, kWh)
|
||
COMFORT_EUR_KH = 2.0 # EUR per K and hour below (heating) or above (cooling) the comfort target
|
||
# while someone is home: above any price (0.30 let a room cool by 1.3 K
|
||
# at a 40 ct peak); pre-heating in cheap hours still pays
|
||
EV_SHORT_EUR_KWH = 1.0 # EUR per kWh the car lacks at departure
|
||
EV_MUST_EUR_KWH = 5.0 # EUR per kWh a car lacks at a "must" ready-by (preferences.py): above any price,
|
||
# below a building's binding load limit (50) and the grid operator's (500)
|
||
MUST_EUR_K = 20.0 # EUR per K and slot across a room's "must" (preferences.py): 80 EUR per K·h, so the
|
||
# heat a room holds (C kWh/K) is not worth letting it fall even at 3 EUR/kWh; it stays
|
||
# inside the bounds and under a building's cap, so those still win
|
||
COST_SOLVE_S = 8.0 # s at most per extra plan for a must's cost (pref_costs)
|
||
COST_MAX = 6 # musts costed per plan at most
|
||
LIGHT_EUR = 0.002 # EUR per step for a closed cover while someone is home in daylight
|
||
CHANGE_EUR_KW = 0.002 # EUR per kW a device's power changes from one step to the next: smooth
|
||
# plans (equal prices would otherwise give any order, and a charger or
|
||
# boiler must not be switched back and forth)
|
||
CLOSED_EUR = 0.00002 # EUR per step for a closed cover: open when nothing is at stake
|
||
COVER_MOVE_EUR = 0.01 # EUR per full travel of a cover the plan places on its window's facts (ENG, G3: no
|
||
# flapping between nearly equal positions; a move a few W of sun pays for is still made)
|
||
MARKET_MAX_W = 100000.0 # W: a contract without a maximum, and the meter's import/export switch
|
||
NO_PRICE_EUR_KWH = 1e-4 # EUR per kWh through the meter and per kWh a device uses, without a tariff
|
||
# only (ENG: a tie-break toward the least energy, not a price)
|
||
SPILL_EUR_KWH = 1e-3 # EUR per kWh of PV curtailed (ENG: never curtail while the meter takes it;
|
||
# above NO_PRICE_EUR_KWH so export wins over spill without a tariff)
|
||
END_VALUE_KEY = "battery.end_value_pct" # the Parameters page's (via the tariff bundle's params): % of the
|
||
# mean feed-in price a kWh left in the battery at the end is worth
|
||
WEAR_KEY = "battery.wear_ct" # the Parameters page's (via the tariff bundle's params): net ct per kWh a battery
|
||
# discharges, its ageing per kWh cycled (the owner's battery algorithm, 2026-11-12:
|
||
# in every decision, as the building's battery_core); a device's own wear_ct wins
|
||
END_VALUE_GAP_CT = 0.5 # ct/kWh: the end value at least this far below the cheapest import price (ENG: never
|
||
# buy grid energy into the battery only to keep it; building/mieterstrom.py's twin)
|
||
GRID_MAX_W = 43470.0 # W: the site's connection when the state does not say (state["grid_max_w"],
|
||
# config grid_max_w): a German house connection's usual 63 A main fuse,
|
||
# 3 x 230 V x 63 A
|
||
CO2_KEY = "co2.planner_eur_per_t" # the Parameters page's (via the tariff bundle's params): EUR per t of CO2 the
|
||
# plan weighs on its grid import, gas and district heat (0: cost only)
|
||
CO2_BASIS_KEY = "co2.basis" # the Parameters page's: direct | lifecycle (the plan reports which)
|
||
LEGIONELLA_EVERY = 4 # steps: a tank's legionella run is checked on the hour (ENG: a binary per hour, not
|
||
# per step: solve time)
|
||
RELAY_STEPS = 4 # steps: a tank element's relay is on or off for a whole hour in the plan (ENG: solve
|
||
# time; the guard's min_switch_s keeps it from cycling faster anyway)
|
||
STORE_TIE_EUR_WH = 1e-8 # EUR per Wh held above the floor per step, only for a battery with a standby (ENG: a
|
||
# tie-break, 0.1 ct per kWh and day: with a flat price, charging the standby ahead or
|
||
# step by step costs the same; the plan holds the floor instead of a buffer)
|
||
REFILL_STEPS = 48 # steps: a battery that starts under the plan's reserve (above its top) is back inside it
|
||
# within 12 h, at the steps the plan finds cheapest, or later where its power needs longer
|
||
# (ENG, A2.3a; the building plan's REFILL_SLOTS, C6.5): never at once from the grid by force
|
||
STANDBY_GRID_EUR_KWH = 1.0 # EUR per kWh of a battery's standby drawn from the grid where the battery could give it
|
||
# (ENG, A2.3 S.2: above any price, so the standby comes from the cells while they hold
|
||
# charge, as it does physically; the grid only where the battery cannot: a valve)
|
||
|
||
|
||
class Model:
|
||
def __init__(self, s: dict):
|
||
self.s = s
|
||
self.T, self.dt = s["steps"], s["step_s"] / 3600.0
|
||
self.h = highspy.Highs()
|
||
self.h.setOptionValue("output_flag", False)
|
||
self.flows = [[] for _ in range(self.T)] # (+1 into the house's balance | -1 out of it, var)
|
||
self.cost = [] # (coef, var)
|
||
self.devices = {} # id -> (kind, vars for the plan)
|
||
# False: no tariff, no prices (_prepare); a state not prepared: priced
|
||
# where it has a tariff and an import price for every step
|
||
self.priced = s["priced"] if "priced" in s else (
|
||
(s.get("prices") or {}).get("status", "tariff") != "none" and
|
||
all(v is not None for v in (s.get("price_import") or [None])[:self.T]))
|
||
self.notes: list[str] = [] # what the plan assumed or left out, quietly (no alarm)
|
||
self.co2w = self.co2_weight()
|
||
|
||
def note(self, text: str):
|
||
if text and text not in self.notes:
|
||
self.notes.append(text)
|
||
|
||
# -- CO2 (docs/methods.md A2.15) -------------------------------------------
|
||
def co2_weight(self) -> float:
|
||
"""w, EUR per t of CO2 in the objective: the Parameters page's
|
||
co2.planner_eur_per_t (the tariff bundle's params); 0 (cost only)
|
||
without a tariff, without the parameter (noted) or without any CO2
|
||
factor in the bundle (noted while w > 0; the parameter's absence is
|
||
noted where the bundle has factors to weigh)."""
|
||
if not self.priced:
|
||
return 0.0
|
||
raw = (self.s.get("params") or {}).get(CO2_KEY)
|
||
try:
|
||
w = float(raw)
|
||
except (TypeError, ValueError):
|
||
w = None
|
||
if w is None or not math.isfinite(w) or w < 0:
|
||
if self.s.get("co2"):
|
||
self.note(f"{CO2_KEY} missing: CO2 not weighed (cost only)")
|
||
return 0.0
|
||
if w > 0 and not self.s.get("co2"):
|
||
self.note("no CO2 factors in the tariff: CO2 not weighed")
|
||
return 0.0
|
||
return w
|
||
|
||
def co2_factor(self, carrier: str, t: int) -> float | None:
|
||
"""g CO2 per kWh of a carrier in step t (the bundle's), or None."""
|
||
c = self.s.get("co2") or {}
|
||
if carrier == "electricity":
|
||
xs = c.get("electricity") or []
|
||
v = xs[t] if t < len(xs) else None
|
||
else:
|
||
v = c.get(carrier)
|
||
return float(v) if isinstance(v, (int, float)) and math.isfinite(v) and v >= 0 else None
|
||
|
||
def co2_wh(self, carrier: str, t: int) -> float:
|
||
"""The CO2 term per W held for one step of a carrier's input: w x
|
||
f x dt / 1000 kWh / 1e6 g per t (A2.15); 0 with no weight, and 0
|
||
where the carrier has no factor (that carrier unweighed, noted)."""
|
||
if not self.co2w:
|
||
return 0.0
|
||
f = self.co2_factor(carrier, t)
|
||
if f is None:
|
||
self.note(f"no CO2 factor for {carrier}" + (" in some steps" if carrier == "electricity" else "")
|
||
+ f": {carrier} unweighed there")
|
||
return 0.0
|
||
return self.co2w * f * self.dt / 1000.0 / 1e6
|
||
|
||
# -- a boiler's part load (docs/methods.md E6.4) ----------------------------------
|
||
def boiler_curve(self, cid: str, p: dict, qmax: float, eff: float) -> dict:
|
||
"""A boiler's gas against its heat: its part-load curve (the
|
||
mapping's part_load_curve, else the Parameters page's
|
||
boiler.part_load_<boiler_type>) as segments, the full-load point
|
||
for an on/off one; none: one constant efficiency (noted). {segs,
|
||
convex, gmax (gas W at full heat), full (the full-load efficiency)}."""
|
||
pts, why = part_load(p, self.s.get("params"))
|
||
if pts is None or qmax <= 0:
|
||
why = why if pts is None else "no max_heat_w: one constant efficiency"
|
||
self.note(f"{cid}: {why}")
|
||
return {"segs": None, "convex": True, "gmax": qmax / eff if eff else 0.0, "full": eff, "from": why}
|
||
segs, convex, capped = gas_segments(qmax, eff, pts)
|
||
if capped:
|
||
self.note(f"{cid}: the part-load efficiency held at 1 (no more heat than the gas's Hs)")
|
||
full = min(1.0, eff * relative_efficiency(pts, 1.0))
|
||
return {"segs": segs, "convex": convex, "gmax": sum(dq * sl for dq, sl in segs), "full": full, "from": why}
|
||
|
||
def boiler_step(self, bc: dict, cost: float, switched: bool, qmax: float) -> tuple:
|
||
"""One step's gas input of a boiler and its heat terms ((W of heat
|
||
per W of the variable, variable), ...): on its curve (convex: an LP's
|
||
segments; efficiency rising with load: one binary per segment beyond
|
||
the first, so a segment is used only once the one before is full),
|
||
at its full-load point when switched on/off, else at the one
|
||
efficiency. (gas var, terms)."""
|
||
if switched:
|
||
gmax = qmax / bc["full"] if bc["full"] else 0.0
|
||
u = self.var(0.0, 1.0, integer=True)
|
||
pg = self.var(0.0, gmax, cost=cost)
|
||
self.h.addConstr(pg - gmax * u == 0)
|
||
return pg, [(bc["full"], pg)]
|
||
if not bc["segs"]:
|
||
pg = self.var(0.0, bc["gmax"], cost=cost)
|
||
return pg, [(bc["full"], pg)]
|
||
segs = bc["segs"]
|
||
ds = [self.var(0.0, dq) for dq, _ in segs]
|
||
pg = self.var(0.0, bc["gmax"], cost=cost)
|
||
self.h.addConstr(pg - sum((sl * d for (_, sl), d in zip(segs, ds)), start=Lin()) == 0)
|
||
if not bc["convex"]:
|
||
for k in range(1, len(segs)):
|
||
y = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(ds[k] - segs[k][0] * y <= 0)
|
||
self.h.addConstr(ds[k - 1] - segs[k - 1][0] * y >= 0)
|
||
return pg, [(1.0, d) for d in ds]
|
||
|
||
def var(self, lo=0.0, hi=highspy.kHighsInf, cost=0.0, integer=False):
|
||
v = self.h.addVariable(lb=lo, ub=hi, type=highspy.HighsVarType.kInteger if integer else
|
||
highspy.HighsVarType.kContinuous)
|
||
if cost:
|
||
self.cost.append((cost, v))
|
||
return v
|
||
|
||
def smooth(self, series):
|
||
"""The cost of every change in a power series (W variables or
|
||
expressions), |p[t] - p[t-1]|."""
|
||
for a, b in zip(series, series[1:]):
|
||
d = self.var(cost=CHANGE_EUR_KW / 1000.0)
|
||
self.h.addConstr(d - b + a >= 0)
|
||
self.h.addConstr(d + b - a >= 0)
|
||
|
||
def eur_wh(self, t: int, price_ct: float | None) -> float:
|
||
"""EUR for one W held for one step at this price (None: no price, 0)."""
|
||
return 0.0 if price_ct is None else self.dt / 1000.0 * price_ct / 100.0
|
||
|
||
def use_cost(self, t: int = 0) -> float:
|
||
"""Without a tariff: a device's energy's tie-break weight per W and
|
||
step (NO_PRICE_EUR_KWH; rising a little over the horizon, so of
|
||
equal plans the earlier wins); with one 0 (its prices count)."""
|
||
if self.priced:
|
||
return 0.0
|
||
return self.dt / 1000.0 * NO_PRICE_EUR_KWH * (1.0 + t / max(1, self.T))
|
||
|
||
# -- the house -------------------------------------------------------
|
||
def grid(self):
|
||
"""Import and export through the meter, each at most the site's
|
||
connection (grid_max_w; never below the house's own net load or
|
||
surplus, so there is always a plan). The meter either imports or
|
||
exports in a step: a binary where the feed-in pays at least the
|
||
import price (else importing to export at once would earn money and
|
||
the plan would run to the bound). Elsewhere none is needed: doing
|
||
both costs more than doing less of each, which keeps the balance and
|
||
only loosens every other constraint on the import (all are upper
|
||
bounds: the building's, the grid order's); steps with a market
|
||
contract have their own switch (market)."""
|
||
s = self.s
|
||
cap = float(s.get("grid_max_w") or GRID_MAX_W)
|
||
self.gin, self.gout, self.gcap = [], [], []
|
||
for t in range(self.T):
|
||
net = s["load_w"][t] - s["pv_w"][t]
|
||
hi_in, hi_out = max(cap, net), max(cap, -net)
|
||
if self.priced:
|
||
# the import's price, and its CO2 at the weight (A2.15; no credit for export)
|
||
gi = self.var(0.0, hi_in, cost=self.eur_wh(t, s["price_import"][t]) + self.co2_wh("electricity", t))
|
||
# an unpriced export (None) carries no value: coefficient 0
|
||
go = self.var(0.0, hi_out, cost=-self.eur_wh(t, s["price_export"][t]))
|
||
else:
|
||
gi = self.var(0.0, hi_in, cost=self.dt / 1000.0 * NO_PRICE_EUR_KWH)
|
||
go = self.var(0.0, hi_out, cost=self.dt / 1000.0 * NO_PRICE_EUR_KWH)
|
||
spill = self.var(0.0, max(0.0, s["pv_w"][t]), cost=self.dt / 1000.0 * SPILL_EUR_KWH)
|
||
self.gin.append(gi)
|
||
self.gout.append(go)
|
||
self.gcap.append((hi_in, hi_out))
|
||
self.flows[t] += [(1, gi), (-1, go), (-1, spill)]
|
||
|
||
def grid_switch(self, skip):
|
||
"""The meter's import/export switch where the feed-in pays at least
|
||
the import price (grid), outside the steps in skip (market's own)."""
|
||
s = self.s
|
||
if not self.priced:
|
||
return # both carry the same tiny weight: doing both never pays
|
||
for t in range(self.T):
|
||
pe = s["price_export"][t] if s["price_export"][t] is not None else 0.0 # unpriced: worth nothing
|
||
if t in skip or pe < s["price_import"][t]:
|
||
continue
|
||
hi_in, hi_out = self.gcap[t]
|
||
imp = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(self.gin[t] - hi_in * imp <= 0)
|
||
self.h.addConstr(self.gout[t] + hi_out * imp <= hi_out)
|
||
|
||
def market(self):
|
||
"""The market's contracts in force (state["market"], bundles.py
|
||
market_for_model; shadow, the market's step 2): a contract the home
|
||
buys on is an import source at its price, one it sells on an export
|
||
sink, both through the same meter as the grid. Bounds per step: the
|
||
best-effort maximum; a firm amount (bought: at least that much; sold:
|
||
a shortfall costs the contract's price again, a stand-in for its
|
||
penalty); take-or-pay (the minimum is paid whether used or not). The
|
||
meter either imports or exports in a step (a binary where a contract
|
||
applies), so nothing bought is resold."""
|
||
self.buy = [[] for _ in range(self.T)] # contract import vars per step
|
||
self.sell = [[] for _ in range(self.T)]
|
||
self.contracts = [] # (contract, {step: var}, {step: paid var})
|
||
steps = set()
|
||
for c in self.s.get("market") or []:
|
||
vars_, paid_ = {}, {}
|
||
for t in range(max(0, c["from_step"]), min(self.T, c["to_step"])):
|
||
k = term_at(c, t) # this step's terms (the coming slots), else the contract's
|
||
if k is None:
|
||
continue
|
||
hi = k["max_w"] if k.get("max_w") else MARKET_MAX_W
|
||
eur = self.eur_wh(t, k["price_ct"])
|
||
if c["direction"] == "buys":
|
||
lo = min(k.get("guaranteed_w") or 0.0, hi)
|
||
mwh = k.get("minimum_wh") or 0.0
|
||
if mwh > 0: # take-or-pay: what is paid covers at least the minimum
|
||
v = self.var(lo, hi)
|
||
paid = self.var(mwh / self.dt, cost=eur)
|
||
self.h.addConstr(paid - v >= 0)
|
||
paid_[t] = paid
|
||
else:
|
||
v = self.var(lo, hi, cost=eur)
|
||
self.buy[t].append(v)
|
||
self.flows[t].append((1, v))
|
||
else:
|
||
v = self.var(0.0, hi, cost=-eur)
|
||
g = min(k.get("guaranteed_w") or 0.0, hi)
|
||
if g > 0:
|
||
short = self.var(cost=eur)
|
||
self.h.addConstr(v + short >= g)
|
||
self.sell[t].append(v)
|
||
self.flows[t].append((-1, v))
|
||
vars_[t] = v
|
||
steps.add(t)
|
||
self.contracts.append((c, vars_, paid_))
|
||
for t in steps:
|
||
imp = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(sum(self.buy[t], start=Lin()) + self.gin[t] - MARKET_MAX_W * imp <= 0)
|
||
self.h.addConstr(sum(self.sell[t], start=Lin()) + self.gout[t] + MARKET_MAX_W * imp <= MARKET_MAX_W)
|
||
self.grid_switch(steps)
|
||
|
||
def meter_in(self, t):
|
||
"""The meter's import in step t: the grid's and the contracts' bought."""
|
||
return self.gin[t] + sum(self.buy[t], start=Lin()) if self.buy[t] else self.gin[t]
|
||
|
||
def building(self):
|
||
"""The building's load limit and shift request (on the meter's import)."""
|
||
req = self.s.get("building") or {}
|
||
lim = req.get("load_limit")
|
||
if lim:
|
||
for t in range(lim["from_step"], lim["to_step"]):
|
||
over = self.var(cost=lim["penalty"] * self.dt / 1000.0)
|
||
self.h.addConstr(self.meter_in(t) - over <= lim["value"])
|
||
sh = req.get("shift_request")
|
||
if sh:
|
||
a, b = sh["from_step"], sh["to_step"]
|
||
base = sum(max(0.0, self.s["load_w"][t] - self.s["pv_w"][t]) * self.dt for t in range(a, b))
|
||
target = max(0.0, base - sh["value"] * 1000.0)
|
||
miss = self.var(cost=sh["penalty"] / 1000.0)
|
||
imp = sum((self.dt * self.meter_in(t) for t in range(a, b)), start=Lin())
|
||
self.h.addConstr(imp - miss <= target)
|
||
|
||
def battery_plan(self):
|
||
"""The building's plan for its battery (state["building"]
|
||
["battery_plan"], building.py; docs/methods.md A9.3): per step it
|
||
covers, the battery's grid-side power (charge - discharge) tracks
|
||
the target, each W off it costing penalty x dt / 1000 (EUR per kWh
|
||
of deviation). A site with several batteries: their sum tracks it.
|
||
The SoC bounds and the owner's reserve (PENALTY_LIMIT, per % and
|
||
step) cost far more, so they win; no battery planned: nothing.
|
||
|
||
A battery bound to a building (state["building"]["battery_bound"],
|
||
A9.4): it charges more than the building's plan only from the
|
||
house's PV surplus (a reserve below its floor is refilled from PV,
|
||
from the grid only as far as the plan itself charges); a step no
|
||
plan covers (lapsed, or beyond its window) is self-consumption only:
|
||
charged from the PV surplus, discharged for the house's own use,
|
||
never from or into the grid for the box's own tariff."""
|
||
bld = self.s.get("building") or {}
|
||
bp, bound = bld.get("battery_plan"), bld.get("battery_bound")
|
||
bats = [v for kind, v in self.devices.values() if kind == "battery" and v]
|
||
if not bats or not (bp or bound):
|
||
return
|
||
ws = bp["schedule_w"] if bp else []
|
||
a, b = (max(0, bp["from_step"]), min(self.T, bp["to_step"], len(ws))) if bp else (0, 0)
|
||
load, pv = self.s["load_w"], self.s["pv_w"]
|
||
for t in range(self.T):
|
||
w = ws[t] if a <= t < b else None
|
||
if w is None and not bound:
|
||
continue
|
||
net = sum((v["ch"][t] - v["dis"][t] for v in bats), start=Lin())
|
||
surplus, deficit = max(0.0, pv[t] - load[t]), max(0.0, load[t] - pv[t])
|
||
if w is not None:
|
||
pos = self.var(cost=bp["penalty"] * self.dt / 1000.0)
|
||
neg = self.var(cost=bp["penalty"] * self.dt / 1000.0)
|
||
self.h.addConstr(net - pos + neg == float(w))
|
||
if bound:
|
||
# above the building's W only from the PV surplus: never the box's own grid charging
|
||
self.h.addConstr(net <= max(float(w), 0.0) + surplus)
|
||
else:
|
||
# self-consumption only (no building plan covers the step)
|
||
self.h.addConstr(net <= surplus)
|
||
self.h.addConstr(net >= -deficit)
|
||
if bound and bound.get("lapsed"):
|
||
self.notes.append(f"the battery plan of building {bound['building']} ended "
|
||
f"{time.strftime('%d %b %H:%M UTC', time.gmtime(bound.get('until') or 0))} and was not renewed: "
|
||
"the battery runs in self-consumption only (no grid charging) until the next one")
|
||
|
||
def grid_order(self):
|
||
"""The grid operator's limit on the controllable consumers' draw."""
|
||
o = self.s.get("grid_order") or {}
|
||
if not o:
|
||
return
|
||
for t in range(o["from_step"], min(o["to_step"], self.T)):
|
||
base = max(0.0, self.s["load_w"][t] - self.s["pv_w"][t])
|
||
over = self.var(cost=o["penalty"] * self.dt / 1000.0)
|
||
self.h.addConstr(self.meter_in(t) - over <= base + o["limit_w"])
|
||
|
||
def balance(self):
|
||
s = self.s
|
||
for t in range(self.T):
|
||
expr = sum((sign * v for sign, v in self.flows[t]), start=Lin())
|
||
self.h.addConstr(expr == s["load_w"][t] - s["pv_w"][t])
|
||
|
||
# -- devices ---------------------------------------------------------
|
||
def end_value(self) -> float:
|
||
"""V, ct per kWh left in a battery at the plan's end (docs/methods.md
|
||
A2.5, as the building's D5.17): the Parameters page's
|
||
battery.end_value_pct (state["params"], the tariff bundle's) of the
|
||
horizon's mean export price, at most END_VALUE_GAP_CT below its
|
||
cheapest import price (never grid energy bought only to keep it),
|
||
never below 0. 0 without a tariff, without an export price or
|
||
without the parameter (noted: self.end_note)."""
|
||
if hasattr(self, "_end_v"):
|
||
return self._end_v
|
||
self._end_v, self.end_note = 0.0, ""
|
||
if not self.priced:
|
||
return 0.0
|
||
raw = (self.s.get("params") or {}).get(END_VALUE_KEY)
|
||
try:
|
||
pct = float(raw)
|
||
except (TypeError, ValueError):
|
||
pct = None
|
||
if pct is None or not math.isfinite(pct):
|
||
self.end_note = f"{END_VALUE_KEY} missing: the battery's charge at the end valued at 0"
|
||
return 0.0
|
||
pe = [p for p in (self.s.get("price_export") or [])[:self.T] if p is not None]
|
||
if not pe:
|
||
self.end_note = "no export price: the battery's charge at the end valued at 0"
|
||
return 0.0
|
||
v = pct / 100.0 * sum(pe) / len(pe)
|
||
cheapest = min(self.s["price_import"][:self.T])
|
||
if v > cheapest - END_VALUE_GAP_CT:
|
||
v = cheapest - END_VALUE_GAP_CT
|
||
self.end_note = (f"the battery's end value capped at {max(0.0, v):.1f} ct/kWh, "
|
||
f"{END_VALUE_GAP_CT:g} ct below the cheapest import price")
|
||
self._end_v = max(0.0, v)
|
||
return self._end_v
|
||
|
||
def wear(self, p: dict) -> tuple[float, str]:
|
||
"""The battery's wear (ct per kWh discharged) and where it came from: the device's own wear_ct, else the
|
||
Parameters page's battery.wear_ct (state["params"]); 0 without a tariff (nothing is priced) or without
|
||
either (as before 2026-11-12: "none")."""
|
||
if not self.priced:
|
||
return 0.0, "none"
|
||
for raw, src in ((p.get("wear_ct"), "device"), ((self.s.get("params") or {}).get(WEAR_KEY), "parameter")):
|
||
try:
|
||
v = float(raw)
|
||
except (TypeError, ValueError):
|
||
continue
|
||
if math.isfinite(v) and v >= 0:
|
||
return v, src
|
||
return 0.0, "none"
|
||
|
||
def battery(self, d):
|
||
p, st, b = d["params"], d["state"], d["bounds"]
|
||
cap = max(1.0, float(p["capacity_wh"]))
|
||
eff = float(p["efficiency"])
|
||
lo_pct, hi_pct = b["soc_pct"][0], b["soc_pct"][1]
|
||
plo, phi = b["power_w"][0], b["power_w"][1]
|
||
max_ch = max(0.0, min(float(p["max_charge_w"]), phi))
|
||
max_dis = max(0.0, min(float(p["max_discharge_w"]), -plo))
|
||
soc0 = cap * min(max(float(st["soc_pct"]), 0.0), 100.0) / 100.0
|
||
soc, prev, ch, dis = [], soc0, [], []
|
||
pref = d.get("pref") # the owner's reserve per step (preferences.py)
|
||
floors = []
|
||
# the plan's reserve and top (the owner's battery algorithm, A2.3a: the Parameters rows battery.plan_reserve_pct
|
||
# and battery.plan_max_soc_pct, inputs.battery_rows): the battery's own window narrowed by them (the shared
|
||
# battery_core.window); a start under the reserve (or above the top) stays outside until refill_k / drain_k,
|
||
# moved back where the plan finds it cheapest, never at once by force
|
||
wlo, whi = battery_core.window(lo_pct, hi_pct, p.get("plan_reserve_pct"), p.get("plan_max_soc_pct"))
|
||
s0 = 100.0 * soc0 / cap
|
||
refill_k = drain_k = 0
|
||
if s0 < wlo - 1e-9 and wlo > lo_pct:
|
||
per = max_ch * eff * self.dt / cap * 100.0 # % a step at full charge
|
||
refill_k = max(REFILL_STEPS, math.ceil((wlo - s0) / per) + 1) if per > 0 else self.T
|
||
if s0 > whi + 1e-9 and whi < hi_pct:
|
||
per = max_dis / eff * self.dt / cap * 100.0
|
||
drain_k = max(REFILL_STEPS, math.ceil((s0 - whi) / per) + 1) if per > 0 else self.T
|
||
self.window_used = getattr(self, "window_used", {})
|
||
self.window_used[d["id"]] = {"floor_pct": round(wlo, 2), "top_pct": round(whi, 2),
|
||
"reserve_pct": p.get("plan_reserve_pct"), "max_soc_pct": p.get("plan_max_soc_pct"),
|
||
"max_discharge_w": round(max_dis), "refill_steps": refill_k, "drain_steps": drain_k}
|
||
# the idle loss (A2.3, S.2): the system's standby p0 (W) from the battery while it holds charge
|
||
# (lb), from the grid only where it cannot (lg: a valve at STANDBY_GRID_EUR_KWH, into the house's
|
||
# balance only where the mapping says the load does not hold it); the cells' self-discharge as
|
||
# phi per step. Facts with their source (inputs.model_state); none: 0 (noted there)
|
||
p0 = max(0.0, float(p.get("standby_w") or 0.0))
|
||
lam_h = max(0.0, float(p.get("self_discharge_pct_month") or 0.0)) / 100.0 / HOURS_PER_MONTH
|
||
phi = (1.0 - lam_h) ** self.dt
|
||
grid_side = p.get("standby_in_load") is False
|
||
wear_ct, wear_src = self.wear(p)
|
||
wear_eur = wear_ct / 100.0 * self.dt / 1000.0 # EUR per W discharged over a step
|
||
self.wear_used = getattr(self, "wear_used", {})
|
||
self.wear_used[d["id"]] = {"ct": wear_ct, "src": wear_src}
|
||
lbs, lgs = [], []
|
||
for t in range(self.T):
|
||
base_lo = max(lo_pct, min(wlo, s0)) if t < refill_k else wlo
|
||
hi_t = min(hi_pct, max(whi, s0)) if t < drain_k else whi
|
||
lo_t = base_lo
|
||
if pref and not (pref.get("off") is not None and pref["group"][t] == pref["off"]):
|
||
lo_t = min(max(base_lo, pref["floor_pct"][t]), hi_pct)
|
||
floors.append(lo_t)
|
||
c = self.var(0.0, max_ch, cost=self.use_cost(t))
|
||
x = self.var(0.0, max_dis, cost=self.use_cost(t) + wear_eur)
|
||
z = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(c - max_ch * z <= 0)
|
||
self.h.addConstr(x + max_dis * z <= max_dis)
|
||
e = self.var(0.0, cap, cost=STORE_TIE_EUR_WH if p0 > 0 else 0.0)
|
||
under = self.var(cost=PENALTY_LIMIT / cap * 100) # Wh below the floor, per % of the battery
|
||
over = self.var(cost=PENALTY_LIMIT / cap * 100)
|
||
if p0 > 0:
|
||
lb = self.var(0.0, p0)
|
||
lg = self.var(0.0, p0, cost=STANDBY_GRID_EUR_KWH * self.dt / 1000.0)
|
||
self.h.addConstr(lb + lg == p0)
|
||
if grid_side:
|
||
self.flows[t].append((-1, lg))
|
||
self.h.addConstr(e - phi * prev - self.dt * eff * c + self.dt / eff * x + self.dt * lb == 0)
|
||
lbs.append(lb)
|
||
lgs.append(lg)
|
||
else:
|
||
self.h.addConstr(e - phi * prev - self.dt * eff * c + self.dt / eff * x == 0)
|
||
self.h.addConstr(e + under >= lo_t / 100.0 * cap)
|
||
self.h.addConstr(e - over <= hi_t / 100.0 * cap)
|
||
self.flows[t] += [(-1, c), (1, x)]
|
||
soc.append(e)
|
||
ch.append(c)
|
||
dis.append(x)
|
||
prev = e
|
||
# the end value (docs/methods.md A2.5, as the building's D5.17): the
|
||
# last charge is free within its bounds, each kWh left in it worth V
|
||
# (without a tariff nothing is drained for a price anyway: V 0)
|
||
v_ct = self.end_value()
|
||
if v_ct:
|
||
self.cost.append((-v_ct / 100.0 / 1000.0, prev))
|
||
self.smooth([c - x for c, x in zip(ch, dis)])
|
||
self.devices[d["id"]] = ("battery", {"ch": ch, "dis": dis, "soc": soc, "cap": cap, "max_dis": max_dis,
|
||
"floor_wh": wlo / 100.0 * cap, "floors": floors,
|
||
"max_ch": max_ch, "eff": eff, "soc0": soc0, "hi_wh": whi / 100.0 * cap,
|
||
"p0": p0, "phi": phi, "lam_h": lam_h, "lb": lbs, "lg": lgs,
|
||
"grid_side": grid_side, "in_load": p.get("standby_in_load")})
|
||
|
||
def room(self, d, cooling: bool, gains):
|
||
p, st, b = d["params"], d["state"], d["bounds"]
|
||
r, c = float(p["r_k_per_kw"]), float(p["c_kwh_per_k"])
|
||
# the device's electric power and COP: facts (inputs.room_refusal / heating_refusal left out
|
||
# a room without them); a boiler or a heat station draws no electricity in the plan
|
||
elec = cooling or str(p.get("heat_source") or "electric") in ("electric", "heat_pump", "hybrid")
|
||
pmax = float(p["max_power_w"]) if elec else 0.0
|
||
cop = float(p["cop"]) if p.get("cop") is not None else 0.0 # 0: none (a curve alone, or no electricity)
|
||
lo, hi = b["temp_c"][0], b["temp_c"][1]
|
||
comfort = float(p["comfort_c"])
|
||
other = float(p["setup_c"] if cooling else p["setback_c"])
|
||
t0 = st.get("temp_c")
|
||
t0 = float(t0) if t0 is not None else comfort
|
||
switched = not cooling and "switch" in d["channels"] and "climate" not in d["channels"]
|
||
temps, powers, prev = [], [], t0
|
||
band = [] # per step the owner's band (the shift envelope's: shift_envelope)
|
||
# what makes the heat (module docstring; inputs.py refused it where a price or fact is missing)
|
||
src = "electric" if cooling else str(p.get("heat_source") or "electric")
|
||
# facts and parameters, never defaults: inputs.heating_refusal left out a control without them
|
||
eff = float(p["boiler_efficiency"]) if src in ("boiler", "hybrid") else None
|
||
qmax = float(p["max_heat_w"]) if src in ("boiler", "hybrid", "district") else 0.0
|
||
# a boiler's gas or a heat station's heat against the room's heat, at its carrier's price and CO2 (E6)
|
||
sup = HeatSupply(self, d["id"], p, "district" if src == "district" else "boiler",
|
||
switched and src == "boiler") if src in ("boiler", "hybrid", "district") else None
|
||
gmax = sup.gmax if sup and src != "district" else 0.0
|
||
switch_eur = float((self.s.get("params") or {})["heat.hybrid_switch_eur"]) if src == "hybrid" else 0.0
|
||
t_out = self.s["t_out"]
|
||
cops = [cop_at(p, t_out[t]) if p.get("cop_curve") else cop for t in range(self.T)]
|
||
els, gss, dhs, hxs, bxs, prev_u = [], [], [], [], [], None
|
||
hts, occs = [], [] # per step the heat's terms; the occupancy the target used
|
||
if src == "hybrid" and st.get("source") in ("heat_pump", "boiler"):
|
||
prev_u = 1.0 if st["source"] == "heat_pump" else 0.0 # the source now: a change from it counts
|
||
a = self.dt / (r * c)
|
||
internal = self.hourly(p.get("internal_gain_w") or 0.0)
|
||
solar = float(p.get("solar_m2") or 0.0)
|
||
ghi = self.s.get("ghi_w_m2") or [0.0] * self.T
|
||
pref = d.get("pref") # the owner's schedule and overrides (preferences.py)
|
||
# the comfort band (comfort.py, G5): only without the owner's schedule, which wins
|
||
cband = d.get("band") if not pref else None
|
||
# the flat's air and mass (2R2C, B17; G2 in the plan): the room as its share of the flat
|
||
zone = p.get("zone")
|
||
ad = bd = None
|
||
mprev = None
|
||
zgain = [0.0] * self.T
|
||
if zone:
|
||
ad, bd = rc2_discrete(zone, self.dt)
|
||
mprev = zone.get("theta_m0")
|
||
if mprev is None:
|
||
mprev = (zone["r_e"] * t0 + zone["r_i"] * self.s["t_out"][0]) / (zone["r_i"] + zone["r_e"])
|
||
load = self.s.get("load_w") or [0.0] * self.T
|
||
pres = self.s.get("presence_w") or [float(o) for o in self.s["occupied"]]
|
||
# the household's electricity and the people as heat (the fit's shares; the room's share of them)
|
||
zgain = [float(zone.get("el_gain_share") or 0.0) * max(0.0, float(load[t] if t < len(load) else 0.0))
|
||
+ float(zone.get("occ_gain_w") or 0.0) * float(pres[t] if t < len(pres) else 0.0)
|
||
for t in range(self.T)]
|
||
masses, targets = [], []
|
||
cap = (self.s.get("building") or {}).get("thermostat_cap")
|
||
# a combi boiler (Kombitherme, 392; methods.md E6.6): one burner makes the rooms' heat
|
||
# and the hot water. Without a store of its own it heats the water as it is drawn, first: the rooms
|
||
# get what is left of its most heat in each step (the hot-water forecast; without one the rooms keep
|
||
# all of it, noted). With a store (a dhw_tank whose heater is this boiler: shares_with) the store is
|
||
# its own device: its draws come from the store, and the burner's heat is shared (dhw_tank)
|
||
combi = combi_dhw(self, d["id"], p, src) if not cooling else None
|
||
for t in range(self.T):
|
||
terms = [] # (W of heat per W of input, the input)
|
||
pw = pg = ph = None
|
||
if src in ("electric", "heat_pump", "hybrid"):
|
||
if switched and src != "hybrid":
|
||
u = self.var(0.0, 1.0, integer=True)
|
||
pw = self.var(0.0, pmax, cost=self.use_cost(t))
|
||
self.h.addConstr(pw - pmax * u == 0)
|
||
else:
|
||
pw = self.var(0.0, pmax, cost=self.use_cost(t))
|
||
self.flows[t].append((-1, pw))
|
||
terms.append((cops[t], pw))
|
||
if src in ("boiler", "hybrid"):
|
||
pg, bterms = sup.variables(t)
|
||
terms += bterms
|
||
# the burner's heat alone (a hybrid's heat pump apart): what a store it heats shares (dhw_tank)
|
||
bxs.append(sum((k * v for k, v in bterms), start=Lin()))
|
||
if src == "district":
|
||
ph, hterms = sup.variables(t)
|
||
terms += hterms
|
||
if src == "hybrid":
|
||
hu = self.var(0.0, 1.0, integer=True) # 1: the heat pump, 0: the boiler
|
||
self.h.addConstr(pw - pmax * hu <= 0)
|
||
self.h.addConstr(pg + gmax * hu <= gmax)
|
||
if prev_u is not None:
|
||
sw = self.var(cost=switch_eur)
|
||
self.h.addConstr(sw - hu + prev_u >= 0)
|
||
self.h.addConstr(sw + hu - prev_u >= 0)
|
||
prev_u = hu
|
||
els.append(pw)
|
||
gss.append(pg)
|
||
dhs.append(ph)
|
||
heat = sum((k * v for k, v in terms), start=Lin())
|
||
hxs.append(heat)
|
||
hts.append(list(terms))
|
||
if combi is not None:
|
||
self.h.addConstr(heat <= max(qmax - combi[t], 0.0))
|
||
main = pw if pw is not None else pg if pg is not None else ph
|
||
tt = self.var(-50.0, 80.0)
|
||
sign = -1.0 if cooling else 1.0
|
||
covers = gains(t)
|
||
gain = sum((g * gx for g, gx in covers if gx is not None), start=Lin())
|
||
# the fit's (B6): its internal gain, and its sun where no cover carries it; a window's fixed part (G3)
|
||
fixed = internal[t] + (solar * ghi[t] if not covers and t < len(ghi) else 0.0) + zgain[t] \
|
||
+ sum(g for g, gx in covers if gx is None)
|
||
if zone:
|
||
# the air and the mass, exact over the step (B17.4): x_t = Ad x_(t-1) + Bd [T_out, heat into the air in kW]
|
||
mm = self.var(-50.0, 80.0)
|
||
k_air, k_m = bd[0][1] / 1000.0, bd[1][1] / 1000.0
|
||
self.h.addConstr(tt - ad[0][0] * prev - ad[0][1] * mprev - sign * k_air * heat - k_air * gain
|
||
== bd[0][0] * self.s["t_out"][t] + k_air * fixed)
|
||
self.h.addConstr(mm - ad[1][0] * prev - ad[1][1] * mprev - sign * k_m * heat - k_m * gain
|
||
== bd[1][0] * self.s["t_out"][t] + k_m * fixed)
|
||
masses.append(mm)
|
||
mprev = mm
|
||
else:
|
||
# T[t+1] = T[t] (1 - a) + a T_out + dt/C (± heat/1000 + sun gain/1000 + fixed gains/1000);
|
||
# heat: COP x electric W, efficiency x gas W, district W (module docstring)
|
||
self.h.addConstr(tt - (1 - a) * prev - sign * self.dt / c / 1000.0 * heat
|
||
- self.dt / c / 1000.0 * gain == a * self.s["t_out"][t] + self.dt / c / 1000.0 * fixed)
|
||
occ = self.s["occupied"][t + 1] if t + 1 < self.T else self.s["occupied"][t]
|
||
occs.append(occ)
|
||
want, must = (comfort if occ else other), None
|
||
if cband:
|
||
# the band's edge the room keeps (heating: the lower, cooling: the upper) where someone may be
|
||
# home, else the setback (setup); the plan's target for the words and the envelope
|
||
edge = cband["lo"][t] if not cooling else cband["hi"][t]
|
||
w_edge = cband["w_lo"][t] if not cooling else cband["w_hi"][t]
|
||
want = edge if w_edge > 0 else cband["floor"][t]
|
||
occ = 1 if w_edge > 0 else 0
|
||
occs[-1] = occ
|
||
if pref:
|
||
want, must = pref["target"][t], pref["must"][t]
|
||
if pref.get("off") is not None and pref["group"][t] == pref["off"]:
|
||
want, must = pref["base"][t], None # pref_costs: the plan without this group
|
||
target = min(max(want, lo), hi)
|
||
targets.append(target)
|
||
capped = bool(cap) and cap["from_step"] <= t < cap["to_step"]
|
||
# heating: from its target (and must) up to its upper bound (under a building's cap); cooling mirrored
|
||
if cooling:
|
||
b_hi = min(target, must) if must is not None else target
|
||
band.append((max(lo, cap["value"]) if capped else lo, max(min(b_hi, hi), lo)))
|
||
else:
|
||
b_lo = max(target, must) if must is not None else target
|
||
band.append((min(max(b_lo, lo), hi), min(hi, cap["value"]) if capped else hi))
|
||
if must is not None:
|
||
# a bound inside the bounds in force, and under a building's cap
|
||
mv = min(max(must, lo), hi)
|
||
if capped:
|
||
mv = max(mv, cap["value"]) if cooling else min(mv, cap["value"])
|
||
cross = self.var(cost=MUST_EUR_K)
|
||
if cooling:
|
||
self.h.addConstr(tt - cross <= mv)
|
||
else:
|
||
self.h.addConstr(tt + cross >= mv)
|
||
under = self.var(cost=PENALTY_LIMIT)
|
||
over = self.var(cost=PENALTY_LIMIT)
|
||
if cband:
|
||
# G5: the K·h outside the band, each side at its cost weighted by the presence (and the step
|
||
# someone comes home at its own); the setback (setup) held whoever is home
|
||
b_lo = min(max(cband["lo"][t], lo), hi)
|
||
b_hi = min(max(cband["hi"][t], lo), hi)
|
||
cold = self.var(cost=cband["w_lo"][t] * self.dt + (cband["arrive"][t] if not cooling else 0.0))
|
||
warm = self.var(cost=cband["w_hi"][t] * self.dt + (cband["arrive"][t] if cooling else 0.0))
|
||
self.h.addConstr(tt + cold >= b_lo)
|
||
self.h.addConstr(tt - warm <= b_hi)
|
||
back = min(max(cband["floor"][t], lo), hi)
|
||
miss = self.var(cost=cband.get("w_floor", COMFORT_EUR_KH) * self.dt)
|
||
if cooling:
|
||
self.h.addConstr(tt - miss <= back)
|
||
else:
|
||
self.h.addConstr(tt + miss >= back)
|
||
else:
|
||
miss = self.var(cost=COMFORT_EUR_KH * self.dt)
|
||
if cooling:
|
||
self.h.addConstr(tt - miss <= target)
|
||
else:
|
||
self.h.addConstr(tt + miss >= target)
|
||
self.h.addConstr(tt + under >= lo)
|
||
self.h.addConstr(tt - over <= hi)
|
||
if capped:
|
||
miss_cap = self.var(cost=cap["penalty"] * self.dt)
|
||
if cooling:
|
||
self.h.addConstr(tt + miss_cap >= cap["value"]) # cooling: not below the cap
|
||
else:
|
||
self.h.addConstr(tt - miss_cap <= cap["value"]) # heating: not above it
|
||
temps.append(tt)
|
||
powers.append(main)
|
||
prev = tt
|
||
self.smooth(powers if src != "hybrid" else [a_ + b_ for a_, b_ in zip(els, gss)])
|
||
# power: the electric input (None for gas and district heat: no electricity to shed or price);
|
||
# gas, district: their inputs; heat: per step the heat terms
|
||
self.devices[d["id"]] = ("cooling" if cooling else "heating",
|
||
{"temp": temps, "power": els, "gas": gss, "district": dhs, "src": src,
|
||
"fuel": boiler_fuel(p) if src in ("boiler", "hybrid") else None,
|
||
"cops": cops, "eff": eff, "heat": hxs, "qmax": qmax, "burner": bxs,
|
||
"pmax": {"electric": pmax, "heat_pump": pmax, "hybrid": pmax, "boiler": gmax,
|
||
"district": qmax}[src], "switched": switched,
|
||
# the shift envelope (electric sources only): Wh of electricity per K at the mean COP
|
||
"keep": 1 - a, "wh_per_k": 1000.0 * c / (sum(cops) / len(cops)) if cops and min(cops) > 0 else 0.0,
|
||
"band": band,
|
||
# for the heating levers the baseline does not count (heatlevers.py, E14): the
|
||
# room's model, the heat's terms per step, its source's conversion and facts
|
||
"a": a, "k": self.dt / c / 1000.0, "t0": t0, "hterms": hts, "sup": sup,
|
||
"elmax": pmax, "combi": combi, "comfort": comfort, "other": other,
|
||
"lo": lo, "hi": hi, "pref": bool(pref), "occ": occs,
|
||
"bivalent_c": p.get("bivalent_c"),
|
||
# G2, G5: the mass per step (a zone), the target per step, the band in use
|
||
"mass": masses, "targets": targets, "banded": bool(cband), "zone": bool(zone)})
|
||
|
||
def hourly(self, v) -> list[float]:
|
||
"""A number, or 24 by local hour, per step."""
|
||
if not isinstance(v, list):
|
||
return [float(v)] * self.T
|
||
zone = ZoneInfo(self.s.get("tz") or "UTC")
|
||
start, step = self.s["start"], self.s["step_s"]
|
||
return [float(v[datetime.fromtimestamp(start + t * step, timezone.utc).astimezone(zone).hour % len(v)])
|
||
for t in range(self.T)]
|
||
|
||
def ev(self, d):
|
||
p, st, b = d["params"], d["state"], d["bounds"]
|
||
pref = d.get("pref") # the owner's ready-by (preferences.py)
|
||
# not plugged in: nothing, or the session forecast's next session as an
|
||
# expected load (inputs.ev_session; no owner's ready-by): the plan sees
|
||
# it (prices, the battery), nothing acts on it (_entry: no commands)
|
||
exp = st.get("expected") if not st.get("connected") and not pref else None
|
||
if not st.get("connected") and not (exp and exp.get("need_wh") is not None and
|
||
int(exp.get("to_step", 0)) > int(exp.get("from_step", 0))):
|
||
self.devices[d["id"]] = ("ev", None)
|
||
return
|
||
volts = ev_volts(p, "plan")
|
||
imax = min(float(p["max_current_a"]), b["current_a"][1])
|
||
imin = max(float(p["min_current_a"]), b["current_a"][0])
|
||
sess = st.get("session") or {} # the session forecast's, where the car says none
|
||
first = 0
|
||
if exp:
|
||
first, dep, need = int(exp["from_step"]), int(exp["to_step"]), float(exp["need_wh"])
|
||
else:
|
||
if st.get("departure"):
|
||
dep = departure_step(self.s, str(st["departure"]))
|
||
elif sess.get("dep_step") is not None:
|
||
dep = min(self.T, int(sess["dep_step"]))
|
||
else:
|
||
dep = departure_step(self.s, str(p["departure"]))
|
||
need = float(st["need_wh"]) if st.get("need_wh") is not None else \
|
||
float(sess["need_wh"]) if sess.get("need_wh") is not None else float(p["need_wh"])
|
||
if pref:
|
||
dep, need = int(pref["dep_step"]), float(pref["need_wh"])
|
||
if pref.get("off"):
|
||
need = 0.0
|
||
powers, total = [], Lin()
|
||
for t in range(self.T):
|
||
if t < first or t >= dep or imax < imin:
|
||
powers.append(None)
|
||
continue
|
||
y = self.var(0.0, 1.0, integer=True)
|
||
pw = self.var(0.0, imax * volts, cost=self.use_cost(t))
|
||
self.h.addConstr(pw - imax * volts * y <= 0)
|
||
self.h.addConstr(pw - imin * volts * y >= 0)
|
||
self.flows[t].append((-1, pw))
|
||
powers.append(pw)
|
||
total += self.dt * pw
|
||
if pref and pref["how"] == "prefer":
|
||
# a kWh is worth max_ct to the owner (without one: today's), min_kwh at any price
|
||
worth = EV_SHORT_EUR_KWH if pref.get("max_ct") is None else max(0.0, pref["max_ct"]) / 100.0
|
||
short = self.var(cost=worth / 1000.0)
|
||
self.h.addConstr(total + short >= need)
|
||
mwh = min(float(pref.get("min_wh") or 0.0), need)
|
||
if mwh > 0:
|
||
short_min = self.var(cost=EV_SHORT_EUR_KWH / 1000.0)
|
||
self.h.addConstr(total + short_min >= mwh)
|
||
else:
|
||
short = self.var(cost=(EV_MUST_EUR_KWH if pref else EV_SHORT_EUR_KWH) / 1000.0)
|
||
self.h.addConstr(total + short >= need)
|
||
self.smooth([p for p in powers if p is not None])
|
||
self.devices[d["id"]] = ("ev", {"power": powers, "volts": volts, "dep": dep,
|
||
"pmax": imax * volts if imax >= imin else 0.0, "need": need,
|
||
# the ready-by and the energy known (shift_envelope): not the
|
||
# defaults, not a forecast session (expected: not plugged in yet)
|
||
"known": ev_known(st, pref) and not exp, "expected": bool(exp)})
|
||
|
||
def dhw_tank(self, d):
|
||
"""A hot-water tank (docs/methods.md A13; design S.4-S.6): its stored
|
||
heat above the cold water E_t = phi E_(t-1) + dt (Q_t - D_t + u_t - P0)
|
||
with phi = 1 - UA dt / (c_w V), P0 = UA (T_cw - T_room) (the standing
|
||
loss UA (T - T_room) in E); Q its heater's heat (an element's W, a
|
||
heat pump's COP x W, a boiler's gas by its efficiency, district heat);
|
||
D the hot water drawn (the dhw forecast); u the draw it could not
|
||
give (at dhw.short_eur_kwh: never infeasible). Between the comfort's
|
||
E_min (min_temp_c; a Großanlage at least the law's 60 °C, soft here,
|
||
hard in the guard) and E_max (max_temp_c, the device's own maximum).
|
||
A legionella run where the mapping says "plan" and it falls due in
|
||
the horizon: one step at legionella_temp_c, the cheapest (binaries
|
||
over the steps before its due time)."""
|
||
p, st, b = d["params"], d["state"], d["bounds"]
|
||
cw = WATER_WH_PER_L_K * float(p["volume_l"]) # Wh per K
|
||
t_cw = float(p["cold_water_c"])
|
||
room = st.get("room_c") if st.get("room_c") is not None else float(p["room_temp_c"])
|
||
ua = float(p["ua_w_k"])
|
||
phi = 1.0 - ua * self.dt / cw
|
||
p0 = ua * (t_cw - room)
|
||
lo_c = float(p["min_temp_c"])
|
||
if p.get("law_floor_c") is not None:
|
||
lo_c = max(lo_c, float(p["law_floor_c"]))
|
||
hi_c = min(float(p["max_temp_c"]), b["temp_c"][1])
|
||
lo_c = min(lo_c, hi_c)
|
||
emin, emax = cw * (lo_c - t_cw), cw * (hi_c - t_cw)
|
||
e0 = cw * (float(st["temp_c"]) - t_cw)
|
||
short = float(p["short_eur_kwh"]) / 1000.0 * self.dt # EUR per W short for a step
|
||
draw = [max(0.0, float(v)) for v in (d.get("draw_w") or [0.0] * self.T)[:self.T]]
|
||
draw += [0.0] * (self.T - len(draw))
|
||
heater = str(p["heater"])
|
||
switched = heater == "element" and not ({"water_heater", "power"} & set(d.get("channels") or []))
|
||
pmax = float(p.get("max_power_w") or 0.0) if heater in ("element", "heat_pump") else 0.0
|
||
cops = [1.0] * self.T
|
||
if heater == "heat_pump":
|
||
cops = [cop_at(p, self.s["t_out"][t]) if p.get("cop_curve") else float(p["cop"]) for t in range(self.T)]
|
||
sup = HeatSupply(self, d["id"], p, heater) if heater in ("boiler", "district") else None
|
||
shared = burner = None
|
||
if heater == "boiler" and p.get("shares_with"):
|
||
# its boiler is the rooms' boiler (a combi, a system boiler or a hybrid's gas boiler with a
|
||
# store): one burner, the store's heat and the rooms' heat from that burner together
|
||
# at most its heat output (a hybrid's heat pump is not the burner: its heat is not counted)
|
||
kind, rv = self.devices.get(p["shares_with"], (None, None))
|
||
if kind == "heating" and rv and rv.get("src") in ("boiler", "hybrid") and rv.get("qmax") and rv.get("burner"):
|
||
burner = (rv["burner"], rv["qmax"])
|
||
else:
|
||
self.note(f"{d['id']}: its boiler's room control {p['shares_with']} is not planned or has no boiler: "
|
||
"the tank's boiler planned alone")
|
||
if heater == "heat_pump" and p.get("shares_with"):
|
||
kind, rv = self.devices.get(p["shares_with"], (None, None))
|
||
if kind == "heating" and rv and rv.get("power"):
|
||
shared = (rv["power"], rv["pmax"])
|
||
else:
|
||
self.note(f"{d['id']}: its heat pump's room control {p['shares_with']} is not planned: "
|
||
"the tank's heat pump planned alone")
|
||
# legionella (the mapping's "plan"): the due step from its last run (inputs: storefit's)
|
||
leg = st.get("legionella") or {}
|
||
e_leg, window = None, []
|
||
if str(p.get("legionella") or "device") == "plan" and leg.get("due_step") is not None:
|
||
t_leg = float(p["legionella_temp_c"])
|
||
if t_leg > hi_c + 1e-9:
|
||
self.note(f"{d['id']}: legionella run at {t_leg:g} °C above the tank's maximum {hi_c:g} °C: not planned")
|
||
else:
|
||
e_leg = cw * (t_leg - t_cw)
|
||
due = int(leg["due_step"])
|
||
window = list(range(0, min(self.T, due if due > 0 else self.T)))
|
||
# hot water as a reserve (hotwater.py, G7): the floor per step (the draw temperature at the forecast
|
||
# draws, the idle floor between them; a Großanlage the law's, hard), the owner's preferences (107)
|
||
floor_c = [min(max(float(v), 0.0), hi_c) for v in (d.get("floor_c") or [lo_c] * self.T)[:self.T]]
|
||
floor_c += [lo_c] * (self.T - len(floor_c))
|
||
if p.get("law_floor_c") is not None:
|
||
floor_c = [max(v, min(lo_c, hi_c)) for v in floor_c]
|
||
law = p.get("law_floor_c") is not None
|
||
pref = d.get("pref")
|
||
pmin = [None] * self.T # the owner's "must" per step (°C)
|
||
if pref:
|
||
for t in range(self.T):
|
||
c_t = pref["floor"][t]
|
||
if pref.get("off") is not None and pref["group"][t] == pref["off"]:
|
||
continue # pref_costs: the plan without this group
|
||
if c_t is not None:
|
||
floor_c[t] = max(floor_c[t], min(float(c_t), hi_c))
|
||
if pref["must"][t] is not None:
|
||
pmin[t] = min(float(pref["must"][t]), hi_c)
|
||
# a heat pump's COP by the tank's temperature (hotwater.cop_factor): below the draw temperature at its
|
||
# COP there, the heat stored above it at the maximum's (linear: the growth of the energy above it)
|
||
layers = None
|
||
if heater == "heat_pump" and not switched:
|
||
from .hotwater import cop_factor
|
||
r = {"dhw.hp_cop_drop_pct_per_k": float(p.get("hp_cop_drop_pct_per_k") or 0.0),
|
||
"dhw.hp_cop_ref_c": float(p.get("hp_cop_ref_c") or 0.0)}
|
||
mid_c = min(max(float(p["min_temp_c"]), t_cw + 1.0), hi_c)
|
||
f_lo, f_hi = cop_factor(p, mid_c, r), cop_factor(p, hi_c, r)
|
||
if f_hi < f_lo - 1e-6 and mid_c < hi_c - 0.5:
|
||
layers = (cw * (mid_c - t_cw), f_lo, f_hi, mid_c)
|
||
es, pws, gss, dhs, heats, unmet, prev = [], [], [], [], [], [], e0
|
||
lsum = Lin()
|
||
y_prev = max(0.0, e0 - layers[0]) if layers is not None else 0.0
|
||
for t in range(self.T):
|
||
terms, pw, pg, ph = [], None, None, None
|
||
if heater in ("element", "heat_pump"):
|
||
pw = self.var(0.0, pmax, cost=self.use_cost(t))
|
||
if switched:
|
||
# a relay: on or off for a whole hour (RELAY_STEPS: 48 binaries, not 192)
|
||
if t % RELAY_STEPS == 0:
|
||
y = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(pw - pmax * y == 0)
|
||
self.flows[t].append((-1, pw))
|
||
if layers is not None:
|
||
# the heat at the draw temperature's COP, less the extra electricity the heat stored above
|
||
# it takes (x: (1/COP_hi - 1/COP_lo) per Wh the energy above the draw temperature grows, net
|
||
# of its standing loss; linear, no binary: G7)
|
||
x_el = self.var(0.0, pmax)
|
||
self.h.addConstr(x_el - pw <= 0)
|
||
terms += [(cops[t] * layers[1], pw), (-cops[t] * layers[1], x_el)]
|
||
else:
|
||
terms.append((cops[t], pw))
|
||
if shared is not None and shared[0][t] is not None:
|
||
self.h.addConstr(pw + shared[0][t] <= max(shared[1], pmax))
|
||
elif heater == "boiler":
|
||
pg, terms = sup.variables(t)
|
||
else:
|
||
ph, terms = sup.variables(t)
|
||
q = sum((k * v for k, v in terms), start=Lin())
|
||
if burner is not None and t < len(burner[0]):
|
||
self.h.addConstr(q + burner[0][t] <= burner[1])
|
||
# never below the cold water's (or a colder room's) temperature
|
||
e_lb = min(0.0, e0, cw * (room - t_cw))
|
||
e = self.var(e_lb, highspy.kHighsInf)
|
||
u = self.var(0.0, max(draw[t], 0.0), cost=short) # the draw not given
|
||
# Wh under the floor: the short cost; a Großanlage's floor is the law's (PENALTY_LIMIT per K and step)
|
||
w = self.var(cost=PENALTY_LIMIT / cw if law else short)
|
||
over = self.var(cost=PENALTY_LIMIT / cw) # Wh above the maximum (a hot start)
|
||
self.h.addConstr(e - phi * prev - self.dt * q - self.dt * u == -self.dt * (draw[t] + p0))
|
||
self.h.addConstr(e + w >= cw * (floor_c[t] - t_cw))
|
||
self.h.addConstr(e - over <= emax)
|
||
if pmin[t] is not None:
|
||
wm = self.var(cost=MUST_EUR_K / cw) # the owner's must (107)
|
||
self.h.addConstr(e + wm >= cw * (pmin[t] - t_cw))
|
||
if layers is not None:
|
||
# y: the energy above the draw temperature (Wh, at its least: a tie cost); its growth over a
|
||
# step (the part its standing loss does not take) is heat made above it, at the upper COP
|
||
y = self.var(cost=STORE_TIE_EUR_WH)
|
||
self.h.addConstr(y - e >= -layers[0])
|
||
k_el = (1.0 / (cops[t] * layers[2]) - 1.0 / (cops[t] * layers[1])) / self.dt
|
||
if isinstance(y_prev, float): # the first step: the energy above it now
|
||
self.h.addConstr(x_el - k_el * y >= -k_el * phi * y_prev)
|
||
else:
|
||
self.h.addConstr(x_el - k_el * y + k_el * phi * y_prev >= 0)
|
||
y_prev = y
|
||
if e_leg is not None and t in window and t % LEGIONELLA_EVERY == 0:
|
||
lt = self.var(0.0, 1.0, integer=True)
|
||
self.h.addConstr(e - (e_leg - e_lb) * lt >= e_lb)
|
||
lsum += lt
|
||
es.append(e)
|
||
pws.append(pw)
|
||
gss.append(pg)
|
||
dhs.append(ph)
|
||
heats.append(terms)
|
||
unmet.append(u)
|
||
prev = e
|
||
if e_leg is not None and window:
|
||
miss = self.var(cost=PENALTY_LIMIT)
|
||
self.h.addConstr(lsum + miss >= 1)
|
||
self.smooth([v for v in (pws if heater in ("element", "heat_pump") else gss if heater == "boiler" else dhs)])
|
||
self.devices[d["id"]] = ("dhw_tank", {
|
||
"e": es, "power": pws, "gas": gss, "district": dhs, "heat": heats, "unmet": unmet, "draw": draw,
|
||
"cw": cw, "t_cw": t_cw, "room": room, "ua": ua, "phi": phi, "p0": p0, "e0": e0, "emin": emin, "emax": emax,
|
||
"lo_c": lo_c, "hi_c": hi_c, "heater": heater, "pmax": pmax, "switched": switched,
|
||
# the COP the reports and the thermostat's baseline take: at the draw temperature where the plan
|
||
# has the heat pump's two layers (the baseline's thermostat holds that temperature)
|
||
"cops": [c_ * layers[1] for c_ in cops] if layers is not None else cops,
|
||
"eff": sup.curve["full"] if heater == "boiler" else None, "e_leg": e_leg, "window": window,
|
||
"qmax": sup.qmax if sup else None,
|
||
# a boiler-heated tank's fuel (gas or heating oil: the plan's series, plan_series)
|
||
"fuel": sup.carrier if heater == "boiler" and sup else None,
|
||
"src": "electric" if heater in ("element", "heat_pump") else heater,
|
||
# for the store's lever (heatlevers.py): its heater's conversion, its own setpoint without the plan
|
||
"sup": sup, "thermostat_c": p.get("thermostat_c"),
|
||
# G7: the floor per step, the heat pump's two layers (E at the draw temperature, the COP factors)
|
||
"floor_c": floor_c, "law": law, "layers": layers, "pref": bool(pref)})
|
||
|
||
def cover(self, d, room_ids):
|
||
p, b = d["params"], d["bounds"]
|
||
lo, hi = b["position_pct"][0] / 100.0, b["position_pct"][1] / 100.0
|
||
sch = d.get("schedule")
|
||
if sch:
|
||
# the shade's moves by rules (shades.py): fixed here; the room
|
||
# gets the sun on its facade through them
|
||
room = p.get("room") if p.get("room") in room_ids else None
|
||
xs = [self.var(min(max(x / 100.0, 0.0), 1.0), min(max(x / 100.0, 0.0), 1.0)) for x in sch["pos"]] \
|
||
if room else []
|
||
sun = sch["sun"] if sch.get("facade") else self.s["sun"]
|
||
self.devices[d["id"]] = ("cover", {"pos": xs, "gain_w": float(p["gain_w"]), "room": room,
|
||
"schedule": sch, "sun": sun})
|
||
return
|
||
if p.get("room") not in room_ids:
|
||
self.devices[d["id"]] = ("cover", None)
|
||
return
|
||
win = d.get("window")
|
||
xs = []
|
||
for t in range(self.T):
|
||
if win and t < win["hold_steps"] and win.get("hold_pos") is not None:
|
||
# moved by hand: where the inhabitant put it while the guard keeps off it (G3: the override wins)
|
||
hp = min(max(win["hold_pos"], 0.0), 1.0)
|
||
xs.append(self.var(hp, hp))
|
||
continue
|
||
x = self.var(lo, hi)
|
||
closed_any = self.var(cost=CLOSED_EUR)
|
||
self.h.addConstr(closed_any + x >= hi)
|
||
daylight = self.s["sun"][t] > 0.05 and self.s["occupied"][t]
|
||
if daylight:
|
||
closed = self.var(cost=LIGHT_EUR)
|
||
self.h.addConstr(closed + x >= hi)
|
||
if win and xs:
|
||
# G3: no move in the owner's quiet hours; each move costs a little (no flapping)
|
||
if self._quiet(t, p):
|
||
self.h.addConstr(x - xs[-1] == 0)
|
||
else:
|
||
mv = self.var(cost=COVER_MOVE_EUR)
|
||
self.h.addConstr(mv - x + xs[-1] >= 0)
|
||
self.h.addConstr(mv + x - xs[-1] >= 0)
|
||
xs.append(x)
|
||
self.devices[d["id"]] = ("cover", {"pos": xs, "gain_w": float(p["gain_w"]), "room": p["room"],
|
||
**({"window": win} if win else {})})
|
||
|
||
def _quiet(self, t: int, p: dict) -> bool:
|
||
"""A step in a cover's quiet hours (its params quiet_from..quiet_to, local), as A7's rules."""
|
||
from .shades import quiet
|
||
zone = ZoneInfo(self.s.get("tz") or "UTC")
|
||
lt = datetime.fromtimestamp(self.s["start"] + t * self.s["step_s"], timezone.utc).astimezone(zone)
|
||
return quiet(lt, str(p.get("quiet_from", "22:00")), str(p.get("quiet_to", "07:00")))
|
||
|
||
# -- solve -------------------------------------------------------------
|
||
def solve(self, time_limit: float):
|
||
s = self.s
|
||
self.grid()
|
||
self.market()
|
||
covers = [d for d in s["devices"] if d["kind"] == "cover"]
|
||
rooms = {d["id"] for d in s["devices"] if d["kind"] in ("heating", "cooling")}
|
||
for d in covers:
|
||
self.cover(d, rooms)
|
||
for d in s["devices"]:
|
||
k = d["kind"]
|
||
if k == "battery":
|
||
self.battery(d)
|
||
elif k in ("heating", "cooling"):
|
||
t0_room = (d.get("state") or {}).get("temp_c")
|
||
|
||
def gains(t, room=d["id"], t0_room=t0_room):
|
||
# (W per unit open, the cover's position), or (W, None): a fixed gain
|
||
out = []
|
||
for cid, (kind, v) in self.devices.items():
|
||
if kind == "cover" and v and v["room"] == room:
|
||
w = v.get("window")
|
||
if w:
|
||
# G3: the sun through the window after the cover (a closed one keeps its
|
||
# shade_factor out), a closed shutter's lower loss (h_sh x (the room now - outside))
|
||
sun = w["sun_w"][t] if t < len(w["sun_w"]) else 0.0
|
||
dk = max(0.0, float(t0_room) - s["t_out"][t]) if t0_room is not None else 0.0
|
||
out.append((sun * w["shade_factor"] - w["h_sh"] * dk, v["pos"][t]))
|
||
out.append((sun * (1.0 - w["shade_factor"]) + w["h_sh"] * dk, None))
|
||
else:
|
||
out.append((v["gain_w"] * v.get("sun", s["sun"])[t], v["pos"][t]))
|
||
return out
|
||
self.room(d, k == "cooling", gains)
|
||
elif k == "ev":
|
||
self.ev(d)
|
||
for d in s["devices"]:
|
||
if d["kind"] == "dhw_tank":
|
||
self.dhw_tank(d) # after the rooms: a heat pump it shares with is planned
|
||
self.building()
|
||
self.battery_plan()
|
||
self.grid_order()
|
||
self.balance()
|
||
obj = sum((c * v for c, v in self.cost), start=Lin())
|
||
self.h.setOptionValue("time_limit", float(time_limit))
|
||
# tight: the differences between good plans are cents, the total
|
||
# cost euros (a 1 % gap left an EV charging at the evening price)
|
||
self.h.setOptionValue("mip_rel_gap", 1e-4)
|
||
self.h.setOptionValue("mip_abs_gap", 0.002)
|
||
self.h.minimize(obj)
|
||
status = self.h.getModelStatus()
|
||
info = self.h.getInfo()
|
||
if info.primal_solution_status != 2: # no feasible solution
|
||
raise RuntimeError(f"no plan: {self.h.modelStatusToString(status)}")
|
||
return self.h.modelStatusToString(status)
|
||
|
||
|
||
def rc2_discrete(z: dict, dt: float) -> tuple[list, list]:
|
||
"""The 2R2C's exact discrete form over dt hours (methods.md B17.4):
|
||
x = [air, mass], u = [T_out (°C), heat into the air (kW)];
|
||
A = [[-1/(R_i C_a), 1/(R_i C_a)], [1/(R_i C_m), -(1/R_i + 1/R_e)/C_m]],
|
||
B = [[0, 1/C_a], [1/(R_e C_m), 0]]; Ad = exp(A dt), Bd = A^-1 (Ad - I) B.
|
||
A's eigenvalues are real, negative and distinct (an RC network), so
|
||
exp by its eigen-decomposition. (Ad, Bd) as nested lists."""
|
||
ri, re_, ca, cm = float(z["r_i"]), float(z["r_e"]), float(z["c_a"]), float(z["c_m"])
|
||
a11, a12 = -1.0 / (ri * ca), 1.0 / (ri * ca)
|
||
a21, a22 = 1.0 / (ri * cm), -(1.0 / ri + 1.0 / re_) / cm
|
||
tr, det = a11 + a22, a11 * a22 - a12 * a21
|
||
disc = math.sqrt(max(tr * tr / 4.0 - det, 0.0))
|
||
l1, l2 = tr / 2.0 + disc, tr / 2.0 - disc
|
||
e1, e2 = math.exp(l1 * dt), math.exp(l2 * dt)
|
||
if abs(l1 - l2) < 1e-12:
|
||
f0, f1 = e1 * (1 - l1 * dt), e1 * dt # repeated root: exp(A dt) = e (I + (A - l I) dt)
|
||
else:
|
||
f1 = (e1 - e2) / (l1 - l2) # Sylvester: exp(A dt) = f0 I + f1 A
|
||
f0 = (l1 * e2 - l2 * e1) / (l1 - l2)
|
||
ad = [[f0 + f1 * a11, f1 * a12], [f1 * a21, f0 + f1 * a22]]
|
||
# A^-1 (Ad - I)
|
||
inv = [[a22 / det, -a12 / det], [-a21 / det, a11 / det]]
|
||
m = [[ad[0][0] - 1.0, ad[0][1]], [ad[1][0], ad[1][1] - 1.0]]
|
||
g = [[inv[i][0] * m[0][j] + inv[i][1] * m[1][j] for j in range(2)] for i in range(2)]
|
||
b = [[0.0, 1.0 / ca], [1.0 / (re_ * cm), 0.0]]
|
||
bd = [[g[i][0] * b[0][j] + g[i][1] * b[1][j] for j in range(2)] for i in range(2)]
|
||
return ad, bd
|
||
|
||
|
||
# -- heat: what is demanded, and what a source's heat costs (docs/methods.md A2.16, E6) -------
|
||
# Two clean halves, so a store can later sit between them (backlog 329: the
|
||
# hot-water tank, demand -> tank -> heater): heat_demand says what heat a
|
||
# site needs per step that no model in the plan decides; HeatSupply says
|
||
# what one W of heat from a source takes as input and costs (price, CO2,
|
||
# part load). Today the demand is met when it is demanded:
|
||
# HeatSupply.delivered is the one place that says so.
|
||
def is_combi(p: dict) -> bool:
|
||
"""A combi boiler (Kombitherme, 392): the heating control's
|
||
param combi (the mapping's, from the device or its owner): one burner
|
||
for the rooms and the hot water. A store is a device of its own (a
|
||
dhw_tank whose heater is this boiler, shares_with): combi_dhw."""
|
||
return p.get("combi") is True or str(p.get("combi") or "").lower() in ("true", "yes", "1")
|
||
|
||
|
||
def combi_dhw(m: "Model", cid: str, p: dict, src: str) -> list[float] | None:
|
||
"""A combi boiler's hot water per step (W of heat, the site's hot-water
|
||
forecast dhw_w), which it makes first (methods.md E6.6): the rooms'
|
||
heat is capped at its most heat less it. None for any other source, for
|
||
a combi that heats a store of its own (a dhw_tank with heater boiler and
|
||
shares_with this control: the store takes the draws, the burner is shared
|
||
there), or without a forecast (noted: the rooms keep its
|
||
whole output)."""
|
||
if src != "boiler" or not is_combi(p):
|
||
return None
|
||
for t in m.s.get("devices") or []:
|
||
tp = t.get("params") or {}
|
||
if t.get("kind") == "dhw_tank" and str(tp.get("heater") or "") == "boiler" and tp.get("shares_with") == cid:
|
||
return None
|
||
q = heat_demand(m.s, "dhw", m.T)
|
||
if q is None:
|
||
m.note(f"{cid}: a combi boiler without a hot-water forecast: its rooms keep its whole output (no hot-water meter)")
|
||
return None
|
||
return [max(0.0, float(v)) for v in q]
|
||
|
||
|
||
HEAT_DEMANDS = {"space": "heat_w", "dhw": "dhw_w"} # the model bundle's series (B13, B16)
|
||
|
||
|
||
def heat_demand(s: dict, kind: str, steps: int) -> list[float] | None:
|
||
"""The heat (W per step) of a demand the plan takes as it comes: "space"
|
||
the site's heat forecast (heat_w), "dhw" its hot water drawn (dhw_w);
|
||
None without a forecast."""
|
||
xs = s.get(HEAT_DEMANDS[kind])
|
||
if not xs:
|
||
return None
|
||
return [max(0.0, float(v)) for v in xs[:steps]]
|
||
|
||
|
||
class HeatSupply:
|
||
"""One heat source's heat in the plan (E6): a boiler's gas (its part
|
||
load, E6.4; on/off at its full-load point when switched) or district
|
||
heat, each W of input at its carrier's price and CO2 (A2.15). facts:
|
||
boiler_efficiency, max_heat_w, boiler_type, part_load_curve (a heating
|
||
control's params, or the site's: inputs.heat_site). variables(t): its
|
||
input and heat as the MILP's (a room's heat); delivered(demand): a fixed
|
||
heat as numbers (the heat outlook)."""
|
||
|
||
def __init__(self, m: "Model", cid: str, facts: dict, source: str, switched: bool = False):
|
||
self.m, self.cid, self.source, self.switched = m, cid, source, switched
|
||
# a boiler's fuel: gas or heating oil (the control's "fuel", E15); district heat: heat
|
||
self.carrier = boiler_fuel(facts) if source == "boiler" else "heat"
|
||
self.prices = (m.s.get("price_" + self.carrier) or [None] * m.T)
|
||
self.qmax = float(facts.get("max_heat_w") or 0.0)
|
||
self.eff = float(facts["boiler_efficiency"]) if source == "boiler" else None
|
||
self.curve = m.boiler_curve(cid, facts, self.qmax, self.eff) if source == "boiler" else None
|
||
|
||
@property
|
||
def gmax(self) -> float:
|
||
"""The most input (W): a boiler's gas at full heat, a heat station's heat."""
|
||
if self.source != "boiler":
|
||
return self.qmax
|
||
return self.qmax / self.curve["full"] if self.switched else self.curve["gmax"]
|
||
|
||
def cost_wh(self, t: int) -> float:
|
||
"""EUR per W of input held for step t: the carrier's price and its CO2 at the weight."""
|
||
p = self.prices[t] if t < len(self.prices) else None
|
||
return self.m.eur_wh(t, p) + self.m.co2_wh(self.carrier, t)
|
||
|
||
def variables(self, t: int) -> tuple:
|
||
"""Step t's input variable and its heat terms ((W of heat per W of
|
||
the variable, variable), ...) for the MILP."""
|
||
if self.source == "boiler":
|
||
return self.m.boiler_step(self.curve, self.cost_wh(t), self.switched, self.qmax)
|
||
ph = self.m.var(0.0, self.qmax, cost=self.cost_wh(t))
|
||
return ph, [(1.0, ph)]
|
||
|
||
def input_w(self, heat_w: float) -> float:
|
||
"""The input (W) for a heat (W): district heat as it is; a boiler's
|
||
gas on its curve (beyond its most heat at the full-load efficiency),
|
||
else at its one efficiency."""
|
||
q = max(0.0, heat_w)
|
||
if self.source != "boiler":
|
||
return q
|
||
segs = self.curve["segs"]
|
||
if not segs:
|
||
return q / self.eff
|
||
g, left = 0.0, q
|
||
for dq, sl in segs:
|
||
take = min(left, dq)
|
||
g, left = g + take * sl, left - take
|
||
return g + left / self.curve["full"]
|
||
|
||
def delivered(self, demand: list[float]) -> dict:
|
||
"""A demand met when it is demanded (the one place it is said: the
|
||
heat in step t is the demand of step t), as numbers: per step the
|
||
heat and the input (W), and in all the kWh, the cost at the
|
||
carrier's price (steps without one: unpriced_kwh) and the CO2 at its
|
||
factor (None where a step has none)."""
|
||
m = self.m
|
||
heat = [max(0.0, q) for q in demand[:m.T]]
|
||
inputs = [self.input_w(q) for q in heat]
|
||
eur = unpriced = kg = 0.0
|
||
no_factor = False
|
||
for t, w in enumerate(inputs):
|
||
kwh = w * m.dt / 1000.0
|
||
p = self.prices[t] if t < len(self.prices) else None
|
||
if p is None:
|
||
unpriced += kwh
|
||
else:
|
||
eur += kwh * p / 100.0
|
||
f = m.co2_factor(self.carrier, t)
|
||
if f is None:
|
||
no_factor = no_factor or kwh > 0
|
||
else:
|
||
kg += kwh * f / 1000.0
|
||
out = {"heat_w": [round(w) for w in heat], "input_w": [round(w) for w in inputs],
|
||
"heat_kwh": round(sum(heat) * m.dt / 1000.0, 2), "input_kwh": round(sum(inputs) * m.dt / 1000.0, 2),
|
||
"eur": round(eur, 2), "co2_kg": None if no_factor else round(kg, 2)}
|
||
if unpriced:
|
||
out["unpriced_kwh"] = round(unpriced, 2)
|
||
return out
|
||
|
||
|
||
def ev_known(st: dict, pref: dict | None) -> bool:
|
||
"""A car's ready-by and energy are facts: the ready-by the owner's
|
||
preference or the car's (its charger's departure entity), the energy
|
||
the car's (energy-needed entity) or the owner's (kWh, or % with the
|
||
car's state of charge and capacity). The mapping's defaults (need_wh,
|
||
departure) are not; a preference in % without the car's charge falls
|
||
back to them (preferences.py), so it is not either."""
|
||
dep = bool(pref) or st.get("departure") is not None
|
||
need = st.get("need_wh") is not None or bool(pref) and (
|
||
pref.get("kwh") is not None or (pref.get("soc_pct") is not None and bool(pref.get("capacity_wh"))))
|
||
return dep and need
|
||
|
||
|
||
def departure_step(s: dict, hhmm: str) -> int:
|
||
"""The step of the next departure (local time), within the horizon."""
|
||
zone = ZoneInfo(s.get("tz") or "UTC")
|
||
start = datetime.fromtimestamp(s["start"], timezone.utc).astimezone(zone)
|
||
h, m = (int(x) for x in hhmm.split(":"))
|
||
dep = start.replace(hour=h, minute=m, second=0, microsecond=0)
|
||
if dep <= start:
|
||
dep += timedelta(days=1)
|
||
return min(s["steps"], int((dep.timestamp() - s["start"]) // s["step_s"]))
|
||
|
||
|
||
def _round(v: float, step: float) -> float:
|
||
return round(v / step) * step
|
||
|
||
|
||
def _prepare(s: dict) -> dict:
|
||
"""The state as the plan takes it (U1): without a tariff (status none,
|
||
or no import price for the first step) priced False and no market; a
|
||
tariff that prices only the first n steps: the horizon cut to them."""
|
||
pi = s.get("price_import") or []
|
||
status = (s.get("prices") or {}).get("status", "tariff")
|
||
# gas and heat: a boiler's or district heat's steps only while their price lasts
|
||
n = s["steps"]
|
||
srcs = {str((d.get("params") or {}).get("heat_source") or "electric") for d in s.get("devices") or []
|
||
if d["kind"] == "heating"}
|
||
fuels = {boiler_fuel(d.get("params") or {}) for d in s.get("devices") or []
|
||
if d["kind"] == "heating" and str((d.get("params") or {}).get("heat_source") or "") in ("boiler", "hybrid")}
|
||
# a hot-water tank's heater: a tank's boiler is on gas (inputs.tank_refusal asks for the gas price)
|
||
tanks = {str((d.get("params") or {}).get("heater") or "") for d in s.get("devices") or [] if d["kind"] == "dhw_tank"}
|
||
srcs |= tanks
|
||
if "boiler" in tanks:
|
||
fuels.add("gas")
|
||
for key, need in (("price_gas", {"boiler", "hybrid"} if "gas" in fuels else set()),
|
||
("price_oil", {"boiler", "hybrid"} if "oil" in fuels else set()), ("price_heat", {"district"})):
|
||
xs = s.get(key) or []
|
||
if srcs & need and xs:
|
||
n = min(n, next((k for k, v in enumerate(xs) if v is None), len(xs)))
|
||
if n == 0:
|
||
n = s["steps"] # refused upstream (inputs.heating_refusal): nothing to cut for
|
||
if status == "none" or not pi or pi[0] is None:
|
||
s = dict(s, priced=False, market=[])
|
||
return _cut(s, n) if n < s["steps"] else s
|
||
n = min(n, next((k for k, v in enumerate(pi) if v is None), len(pi)))
|
||
s = dict(s, priced=True)
|
||
return _cut(s, n) if n < s["steps"] else s
|
||
|
||
|
||
def _cut(s: dict, n: int) -> dict:
|
||
"""The state for its first n steps: every per-step list (any list of
|
||
the horizon's length, at any depth) cut to n, the step ranges (from_step,
|
||
to_step, dep_step) kept inside it (a car's ready-by beyond it: "beyond")."""
|
||
T = s["steps"]
|
||
|
||
def cut(x):
|
||
if isinstance(x, list):
|
||
return [cut(v) for v in (x[:n] if len(x) == T else x)]
|
||
if isinstance(x, dict):
|
||
y = {k: cut(v) for k, v in x.items()}
|
||
for k in ("from_step", "to_step"):
|
||
if isinstance(y.get(k), int):
|
||
y[k] = min(y[k], n)
|
||
if isinstance(y.get("dep_step"), int) and y["dep_step"] > n:
|
||
y["dep_step"], y["beyond"] = n, True
|
||
return y
|
||
return x
|
||
out = cut(s)
|
||
out["steps"] = n
|
||
return out
|
||
|
||
|
||
def plan(s: dict, time_limit: float = 30.0) -> dict:
|
||
t0 = time.time()
|
||
s = _prepare(s)
|
||
m = Model(s)
|
||
status = m.solve(time_limit)
|
||
val = m.h.getSolution().col_value
|
||
x = lambda v: val[v.index] # noqa: E731
|
||
start, step, T = s["start"], s["step_s"], m.T
|
||
pi = s["price_import"]
|
||
devices = {}
|
||
for d in s["devices"]:
|
||
kind, v = m.devices.get(d["id"], (d["kind"], None))
|
||
entries = []
|
||
for t in range(T):
|
||
e = _entry(d, kind, v, t, x, s, pi, (x(m.gin[t]), x(m.gout[t])))
|
||
if e is not None and (not entries or _key(entries[-1]) != _key(e)):
|
||
entries.append({"t": start + t * step, **e})
|
||
devices[d["id"]] = entries
|
||
market = market_plan(s, m, x)
|
||
energy = energy_of(s, m, x, market)
|
||
heat_cost = carrier_costs(s, m, x)
|
||
# the heat no room model plans (a district-heated or gas home): its expected cost, a fixed term (A2.16)
|
||
outlook = heat_outlook(s, m)
|
||
parts = None
|
||
if energy is not None:
|
||
parts = {"electricity_eur": round(energy, 2), "gas_eur": round(heat_cost["gas_eur"], 2),
|
||
"heat_eur": round(heat_cost["heat_eur"], 2)}
|
||
if heat_cost["oil_eur"]:
|
||
parts["oil_eur"] = round(heat_cost["oil_eur"], 2)
|
||
energy += heat_cost["gas_eur"] + heat_cost["heat_eur"] + heat_cost["oil_eur"]
|
||
if outlook is not None:
|
||
parts["heat_outlook_eur"] = round(outlook["eur"], 2)
|
||
energy += outlook["eur"]
|
||
base = baseline(s, m, x)
|
||
if base is not None and outlook is not None:
|
||
base += outlook["eur"] # the same heat with or without the plan
|
||
out = {"v": 1, "made": int(time.time()), "start": start, "step_s": step, "status": status,
|
||
"solve_s": round(time.time() - t0, 2), "devices": devices, "flex": flexibility(m, x),
|
||
# without a tariff no cost: None, never a cost at a made-up price
|
||
"cost_eur": round(energy, 2) if energy is not None else None,
|
||
"baseline_eur": round(base, 2) if base is not None else None,
|
||
"priced": m.priced, "steps": T, "price_state": s.get("prices") or {},
|
||
"price_note": s.get("price_note", ""), "sources": s.get("sources", {})}
|
||
bats = [v for kind, v in m.devices.values() if kind == "battery" and v]
|
||
if bats and m.priced:
|
||
# the batteries' end value (A2.5): V and the change of their charge at it, not in cost_eur
|
||
v_ct = m.end_value()
|
||
out["battery_end"] = {"value_ct": round(v_ct, 2), "store_eur": round(sum(
|
||
v_ct / 100.0 * (x(b["soc"][-1]) - b["soc0"]) / 1000.0 for b in bats), 2)}
|
||
# the wear on every kWh discharged (the owner's battery algorithm, 2026-11-12) and where it came from
|
||
# the wear's EUR over the horizon per battery: a cost of the plan's own, NOT in cost_eur nor baseline_eur (both
|
||
# are the energy bought and sold; the baseline has no battery): the saving baseline − cost stays on one basis,
|
||
# the wear apart beside it
|
||
wear = {}
|
||
for bid, w in (getattr(m, "wear_used", {}) or {}).items():
|
||
v = m.devices.get(bid, (None, None))[1]
|
||
kwh = sum(x(d) for d in v["dis"]) * m.dt / 1000.0 if v else 0.0
|
||
wear[bid] = {**w, "kwh": round(kwh, 3), "eur": round(kwh * w["ct"] / 100.0, 3)}
|
||
out["battery_wear"] = wear
|
||
# the plan's window and discharge power per battery (the Parameters rows, A2.3a)
|
||
out["battery_window"] = getattr(m, "window_used", {})
|
||
if parts is not None:
|
||
out["cost_parts"] = parts # cost_eur by carrier, the heat outlook a fixed term of its own
|
||
if outlook is not None:
|
||
out["heat_outlook"] = outlook
|
||
# what the stores lose while they hold energy, their facts' sources (design note 10.5)
|
||
storage = storage_report(s, m, x)
|
||
if storage:
|
||
out["storage"] = storage
|
||
co2 = co2_report(s, m, x, outlook)
|
||
if co2 is not None:
|
||
out["co2_kg"] = co2
|
||
out["co2_basis"] = (s.get("co2") or {}).get("basis") or str((s.get("params") or {}).get(CO2_BASIS_KEY) or "")
|
||
# what the plan assumed for want of a fact, or left out (also published; quiet: no alarm): the inputs'
|
||
# notes (inputs.model_state: occupancy, the car's forecast session), the battery's end value, the model's
|
||
notes = [str(n) for n in s.get("notes") or []]
|
||
if getattr(m, "end_note", ""):
|
||
notes.append(m.end_note)
|
||
notes += m.notes
|
||
if notes:
|
||
out["notes"] = notes
|
||
# the site's energy per carrier and use, per step for 24 h (the console's plan chart; methods A2.17)
|
||
series = plan_series(s, m, x, outlook)
|
||
if series:
|
||
out["series"] = series
|
||
steps_eur = step_costs(s, m, x)
|
||
if steps_eur is not None:
|
||
out["steps_eur"] = steps_eur # per step and carrier: with and without the plan (costs.py)
|
||
out["saving_parts"] = saving_parts(s, m, x, steps_eur) # by carrier and lever (plansplit.py, E14)
|
||
if heat_cost["gas_eur"] or heat_cost["heat_eur"] or heat_cost["oil_eur"]:
|
||
out["gas_eur"], out["heat_eur"] = round(heat_cost["gas_eur"], 2), round(heat_cost["heat_eur"], 2)
|
||
if heat_cost["oil_eur"]:
|
||
out["oil_eur"] = round(heat_cost["oil_eur"], 2)
|
||
# rooms not planned (inputs.room_refusal): the thermostat's
|
||
# fallback schedule, and which one in their refusal
|
||
refused = copy.deepcopy(s.get("refused") or {})
|
||
for d in s.get("fallback") or []:
|
||
entries = fallback_entries(s, d)
|
||
if entries:
|
||
devices[d["id"]] = entries
|
||
if d["id"] in refused:
|
||
refused[d["id"]]["fallback"] = ("schedule" if entries else
|
||
"own" if "climate" in d.get("channels", []) else "none")
|
||
if refused:
|
||
out["refused"] = refused # controls not planned, and why (U2, E6)
|
||
if market:
|
||
out["market"] = market
|
||
if any(d.get("pref") for d in s["devices"]) or any(d.get("pref") for d in s.get("fallback") or []):
|
||
out["prefs"] = pref_feedback(s, m, x) + fallback_feedback(s)
|
||
if s.get("prefs_cost") and energy is not None:
|
||
out["prefs_cost"] = pref_costs(s, energy, t0 + time_limit)
|
||
return out
|
||
|
||
|
||
def energy_of(s, m, x, market=None) -> float:
|
||
"""The plan's cost for power (EUR): the grid's import less its feed-in
|
||
(an unpriced export counts nothing), and the market's contracts; None
|
||
without a tariff."""
|
||
if not m.priced:
|
||
return None
|
||
pi, pe = s["price_import"], s["price_export"]
|
||
e = sum(m.eur_wh(t, pi[t]) * x(m.gin[t]) - m.eur_wh(t, pe[t]) * x(m.gout[t]) for t in range(m.T))
|
||
return e + sum(c["cost_eur"] for c in (market if market is not None else market_plan(s, m, x)))
|
||
|
||
|
||
def _when(s, ts: float) -> str:
|
||
return datetime.fromtimestamp(ts, timezone.utc).astimezone(ZoneInfo(s.get("tz") or "UTC")).strftime("%a %H:%M")
|
||
|
||
|
||
TOL_K = 0.3 # a room's target counts as met within this
|
||
TOL_PCT = 0.5 # a battery's reserve
|
||
TOL_WH = 50.0 # a car's energy
|
||
|
||
|
||
def pref_feedback(s, m, x) -> list[dict]:
|
||
"""Per preference (a room's block, boost or away; a car's next ready-by;
|
||
a battery's reserve): met or not in the plan, and in a few words why.
|
||
Fields: control, group, kind, how, label, met (None: not in the
|
||
plan's 48 h, or not plugged in), detail, and per kind the numbers."""
|
||
out = []
|
||
start, step, T = s["start"], s["step_s"], m.T
|
||
for d in s["devices"]:
|
||
pref = d.get("pref")
|
||
if not pref:
|
||
continue
|
||
kind, v = m.devices.get(d["id"], (d["kind"], None))
|
||
if kind in ("heating", "cooling") and v:
|
||
out += _room_feedback(s, d, pref, v, x, kind == "cooling")
|
||
elif kind == "battery" and v:
|
||
for gi, g in enumerate(pref["groups"]):
|
||
ts = [t for t in range(T) if pref["group"][t] == gi]
|
||
f = {"control": d["id"], "group": g["group"], "kind": "battery", "how": "must", "label": g["text"]}
|
||
if not ts:
|
||
out.append(dict(f, met=None, detail="not in the next 48 h"))
|
||
continue
|
||
soc = [100.0 * x(v["soc"][t]) / v["cap"] for t in ts]
|
||
worst = min(range(len(ts)), key=lambda k: soc[k] - v["floors"][ts[k]])
|
||
miss = v["floors"][ts[worst]] - soc[worst]
|
||
met = miss <= TOL_PCT
|
||
f.update(met=met, min_pct=round(min(soc), 1), floor_pct=round(v["floors"][ts[worst]], 1))
|
||
if not met:
|
||
f["detail"] = f"{soc[worst]:.0f} % at {_when(s, start + (ts[worst] + 1) * step)}"
|
||
if d["state"].get("soc_pct") is not None and float(d["state"]["soc_pct"]) < v["floors"][ts[0]]:
|
||
f["detail"] += f" (starts at {float(d['state']['soc_pct']):.0f} %)"
|
||
out.append(f)
|
||
elif kind == "ev":
|
||
out.append(_ev_feedback(s, d, pref, v, x, m))
|
||
elif kind == "dhw_tank" and v:
|
||
# the owner's hot-water times (107): the tank's least planned temperature in each block
|
||
for gi, g in enumerate(pref["groups"]):
|
||
ts = [t for t in range(T) if pref["group"][t] == gi]
|
||
f = {"control": d["id"], "group": g["group"], "kind": "dhw_tank", "how": g["how"], "label": g["text"]}
|
||
if not ts:
|
||
out.append(dict(f, met=None, detail="not in the next 48 h"))
|
||
continue
|
||
temps = [tank_temp(v, t, x) for t in ts]
|
||
worst = min(range(len(ts)), key=lambda k: temps[k])
|
||
met = temps[worst] >= g["c"] - TOL_K
|
||
f.update(met=met, min_c=round(min(temps), 1))
|
||
if not met:
|
||
f["detail"] = f"{temps[worst]:.0f} °C at {_when(s, start + (ts[worst] + 1) * step)}"
|
||
out.append(f)
|
||
return out
|
||
|
||
|
||
def _room_feedback(s, d, pref, v, x, cooling) -> list[dict]:
|
||
out = []
|
||
start, step, T = s["start"], s["step_s"], len(pref["target"])
|
||
lo, hi, lo_by, hi_by = (d["bounds"]["temp_c"] + ["device", "device"])[:4]
|
||
cap = (s.get("building") or {}).get("thermostat_cap")
|
||
sign = -1.0 if cooling else 1.0
|
||
for gi, g in enumerate(pref["groups"]):
|
||
ts = [t for t in range(T) if pref["group"][t] == gi]
|
||
f = {"control": d["id"], "group": g["group"], "kind": g["kind"], "how": g["how"], "label": g["text"]}
|
||
if not ts:
|
||
out.append(dict(f, met=None, detail="not in the next 48 h"))
|
||
continue
|
||
notes = []
|
||
want = []
|
||
for t in ts:
|
||
w0 = pref["must"][t] if g["how"] == "must" and pref["must"][t] is not None else pref["target"][t]
|
||
w = min(max(w0, lo), hi)
|
||
by = (hi_by if not cooling else lo_by) if sign * (w0 - w) > 1e-9 else None
|
||
if cap and cap["from_step"] <= t < cap["to_step"]:
|
||
wc = max(w, cap["value"]) if cooling else min(w, cap["value"])
|
||
if wc != w:
|
||
by, w = "building", wc
|
||
if by and by not in notes:
|
||
notes.append(by)
|
||
want.append(w)
|
||
temps = [x(v["temp"][t]) for t in ts]
|
||
gap = [sign * (w - tt) for w, tt in zip(want, temps)]
|
||
k = max(range(len(ts)), key=lambda i: gap[i])
|
||
met = gap[k] <= TOL_K
|
||
f.update(met=met, first=start + ts[0] * step, worst_c=round(temps[k], 1), want_c=round(want[k], 1))
|
||
bits = []
|
||
if notes:
|
||
held = min(want) if not cooling else max(want)
|
||
bits.append(f"held at {held:g} °C by the {notes[0]}'s limit")
|
||
f["held_by"] = notes[0]
|
||
if not met:
|
||
bits.append(f"{temps[k]:.1f} °C at {_when(s, start + (ts[k] + 1) * step)}")
|
||
if bits:
|
||
f["detail"] = "; ".join(bits)
|
||
out.append(f)
|
||
return out
|
||
|
||
|
||
def _ev_feedback(s, d, pref, v, x, m) -> dict:
|
||
start, step = s["start"], s["step_s"]
|
||
f = {"control": d["id"], "group": pref["group"], "kind": "ev", "how": pref["how"],
|
||
"label": f"car {pref['text']}", "at": pref["at"], "need_kwh": round(pref["need_wh"] / 1000.0, 2)}
|
||
plug = f"; plugged in at {_when(s, pref['plugged_at'])}" if pref.get("plugged_at") else ""
|
||
if pref.get("note"):
|
||
f["note"] = pref["note"]
|
||
if v is None:
|
||
return dict(f, met=None if pref["how"] == "prefer" else False, detail="not plugged in")
|
||
pw = [x(p) if p is not None else 0.0 for p in v["power"]]
|
||
dep = min(v["dep"], len(pw))
|
||
wh = sum(m.dt * p for p in pw[:dep])
|
||
short = max(0.0, pref["need_wh"] - wh)
|
||
pi = s["price_import"]
|
||
f["planned_kwh"] = round(wh / 1000.0, 2)
|
||
f["charge_eur"] = round(sum(m.eur_wh(t, pi[t]) * pw[t] for t in range(dep)), 2) if m.priced else None
|
||
reached = ""
|
||
if pref.get("soc_pct") is not None and pref.get("capacity_wh"):
|
||
pct = min(100.0, float(pref["soc_pct"]) + 100.0 * wh / pref["capacity_wh"])
|
||
f["reached_pct"] = round(pct, 0)
|
||
reached = f"{pct:.0f} %"
|
||
else:
|
||
reached = f"{wh / 1000.0:.1f} kWh"
|
||
when = _when(s, pref["at"])
|
||
if pref.get("beyond"):
|
||
f.update(met=None, detail=f"{reached} by the end of the plan (the ready-by is later){plug}")
|
||
return f
|
||
if pref["how"] == "prefer":
|
||
f["met"] = short <= max(TOL_WH, 0.01 * pref["need_wh"])
|
||
f["detail"] = f"{reached} by {when}" + ("" if f["met"] else
|
||
f" ({short / 1000.0:.1f} kWh less: dearer than the price wanted)") + plug
|
||
return f
|
||
f["met"] = short <= max(TOL_WH, 0.01 * pref["need_wh"])
|
||
if f["met"]:
|
||
f["detail"] = f"{reached} by {when}{plug}"
|
||
return f
|
||
# a must it cannot meet: by how much, and when it could be ready at full power from now
|
||
f["short_kwh"] = round(short / 1000.0, 2)
|
||
rate = v.get("pmax") or 0.0
|
||
if rate > 0:
|
||
n = math.ceil(pref["need_wh"] / (rate * m.dt) - 1e-9)
|
||
f["ready_at"] = int(start + n * step)
|
||
can = f"; ready at full power by {_when(s, f['ready_at'])}"
|
||
else:
|
||
can = "; it may not charge now (a limit holds it at 0 A)"
|
||
f["detail"] = f"{reached} by {when}, short by {short / 1000.0:.1f} kWh{can}{plug}"
|
||
return f
|
||
|
||
|
||
def pref_costs(s, energy: float, deadline: float) -> dict:
|
||
"""Each must's cost (EUR a day): the plan's cost for power less that of
|
||
the plan made again without it (a room's block at its setback, a
|
||
battery's reserve at its floor before); a car's must: what its charging
|
||
costs (no second plan). At most COST_MAX, each within COST_SOLVE_S and
|
||
the time left."""
|
||
out = {}
|
||
days = s["steps"] * s["step_s"] / 86400.0
|
||
n = 0
|
||
for i, d in enumerate(s["devices"]):
|
||
pref = d.get("pref")
|
||
if not pref or d["kind"] not in ("heating", "cooling", "battery", "dhw_tank"):
|
||
continue
|
||
for gi, g in enumerate(pref["groups"]):
|
||
if g["how"] != "must" or gi not in pref["group"]:
|
||
continue
|
||
left = deadline - time.time() - 1.0
|
||
if n >= COST_MAX or left < 1.0:
|
||
return out
|
||
n += 1
|
||
s2 = copy.deepcopy(s)
|
||
s2["prefs_cost"] = False
|
||
s2["devices"][i]["pref"]["off"] = gi
|
||
try:
|
||
m2 = Model(s2)
|
||
m2.solve(min(COST_SOLVE_S, left))
|
||
val = m2.h.getSolution().col_value
|
||
e2 = energy_of(s2, m2, lambda v: val[v.index])
|
||
except Exception: # noqa: BLE001 - a cost is not worth failing the plan
|
||
continue
|
||
c = (energy - e2) / days
|
||
out[g["group"]] = round(c if abs(c) >= 0.005 else 0.0, 2)
|
||
return out
|
||
|
||
|
||
def term_at(c: dict, t: int) -> dict | None:
|
||
"""A market contract's terms in plan step t: its per-step terms when the
|
||
bundle told the coming slots (None: it does not apply then), else the
|
||
contract's own (held over from_step .. to_step)."""
|
||
per = c.get("terms")
|
||
if per is None:
|
||
return c
|
||
return per[t] if 0 <= t < len(per) else None
|
||
|
||
|
||
def contract_energy(m, x, c, vars_, paid_):
|
||
"""A market contract's steps in the plan with energy used or paid:
|
||
(step, kWh used, kWh paid, the step's price ct). A take-or-pay
|
||
contract's paid energy is at least its minimum, used or not."""
|
||
for t, v in sorted(vars_.items()):
|
||
e = max(x(v), 0.0) * m.dt / 1000.0
|
||
pay = max(x(paid_[t]) * m.dt / 1000.0, e) if t in paid_ else e
|
||
if pay < 1e-6:
|
||
continue
|
||
yield t, e, pay, (term_at(c, t) or c)["price_ct"]
|
||
|
||
|
||
def contract_eur(c, e, pay, price) -> float:
|
||
"""What a contract's step costs (EUR; < 0 received): bought, the kWh
|
||
paid at its price; sold, the kWh delivered at its price."""
|
||
return pay * price / 100.0 if c["direction"] == "buys" else -e * price / 100.0
|
||
|
||
|
||
def market_plan(s, m, x) -> list[dict]:
|
||
"""Per contract in the plan (shadow): the planned energy per step and in
|
||
all (kWh), what is paid, and what it saves against the grid: bought,
|
||
import price x kWh used - contract price x kWh paid; sold, (contract
|
||
price - feed-in) x kWh (EUR; < 0: dearer than the grid). A take-or-pay
|
||
contract's paid energy is at least its minimum, used or not (what the
|
||
optimisation pays). Fields: id, name, direction, price_ct, steps [{t,
|
||
kwh, paid_kwh}] (steps with energy used or paid only), planned_kwh,
|
||
paid_kwh, cost_eur (> 0 paid, < 0 received), vs_grid_eur."""
|
||
out = []
|
||
pi, pe = s["price_import"], s["price_export"]
|
||
for c, vars_, paid_ in getattr(m, "contracts", []):
|
||
steps, kwh, paid_kwh, cost, vs = [], 0.0, 0.0, 0.0, 0.0
|
||
for t, e, pay, price in contract_energy(m, x, c, vars_, paid_):
|
||
steps.append({"t": s["start"] + t * s["step_s"], "kwh": round(e, 4), "paid_kwh": round(pay, 4)})
|
||
kwh += e
|
||
paid_kwh += pay
|
||
cost += contract_eur(c, e, pay, price)
|
||
if c["direction"] == "buys":
|
||
vs += (e * pi[t] - pay * price) / 100.0
|
||
else:
|
||
vs += e * (price - (pe[t] or 0.0)) / 100.0 # an unpriced export: worth nothing
|
||
out.append({"id": c["id"], "name": c.get("name", ""), "direction": c["direction"], "price_ct": c["price_ct"],
|
||
"steps": steps, "planned_kwh": round(kwh, 4), "paid_kwh": round(paid_kwh, 4),
|
||
"cost_eur": round(cost, 4), "vs_grid_eur": round(vs, 4)})
|
||
return out
|
||
|
||
|
||
FLEX_STEPS = 96 # 24 h at 15 min: what a building plans with (shed_w, grid_w)
|
||
SHIFT_STEPS = 192 # 48 h: the shift envelope (the band prices' horizon)
|
||
SHIFT_DEVICES = 16 # devices in a shift envelope at most (the fleet's storage bound)
|
||
|
||
|
||
def flexibility(m, x) -> dict:
|
||
"""What the flat could do for its building (the building
|
||
asks for flexibility, it doesn't cap averages; building/README.md hole
|
||
3), per step for the next 24 h: grid_w, the planned import through the
|
||
meter (the grid's and a market contract's: a flat supplied by its
|
||
building's pool imports through a contract, and its gin alone was 0, so
|
||
shed_w was 0 too: docs/methods.md A11); shed_w, how much of it the
|
||
controllable devices (heating, cooling, EV, the battery's charging)
|
||
could drop in that step, plus what the battery could still discharge
|
||
(its spare power, bounded by the energy above its floor): what a
|
||
load_limit can take away without touching the household's own use.
|
||
shift (48 h, shift_envelope): the energy the devices can move, for a
|
||
building's price bands; absent where no device's facts are known."""
|
||
n = min(m.T, FLEX_STEPS)
|
||
bought = [x(m.gin[t]) + sum((x(v) for v in m.buy[t]), 0.0) for t in range(m.T)]
|
||
grid = [round(bought[t]) for t in range(n)]
|
||
shed = [0.0] * n
|
||
for kind, v in m.devices.values():
|
||
if v is None:
|
||
continue
|
||
if kind == "battery":
|
||
for t in range(min(n, len(v["dis"]))):
|
||
# what it holds above its floor after this step's idle loss (S.2)
|
||
stored = (max(v.get("phi", 1.0) * x(v["soc"][t - 1]) - m.dt * v.get("p0", 0.0), 0.0) if t else
|
||
max(x(v["soc"][0]), 0.0)) - v["floor_wh"]
|
||
spare = max(v["max_dis"] - x(v["dis"][t]), 0.0)
|
||
shed[t] += max(min(spare, stored / m.dt if m.dt else 0.0), 0.0)
|
||
cols = v.get("ch") if kind == "battery" else v.get("power")
|
||
for t in range(min(n, len(cols or []))):
|
||
if cols[t] is not None and hasattr(cols[t], "index"): # an EV's steps after departure are empty
|
||
shed[t] += max(x(cols[t]), 0.0)
|
||
out = {"grid_w": grid, "shed_w": [round(min(sh, g)) for sh, g in zip(shed, grid)],
|
||
"net_w": [round(bought[t] - x(m.gout[t]) - sum((x(v) for v in m.sell[t]), 0.0)) for t in range(n)]}
|
||
sh = shift_envelope(m, x)
|
||
if sh:
|
||
out["shift"] = sh
|
||
return out
|
||
|
||
|
||
|
||
def plan_series(s, m, x, outlook) -> dict:
|
||
"""The plan's energy picture per step for the next 24 h (FLEX_STEPS; W,
|
||
the mean power in the step: docs/methods.md A2.17), for the console's
|
||
plan chart: electricity's sources (import_w, pv_w: the forecast, the
|
||
battery's discharge) and uses (load_w: the house's own forecast,
|
||
heating_w / cooling_w: electric heat and cooling, ev_w, dhw_element_w:
|
||
a tank's electric heater, the battery's charge, export_w), and the other
|
||
carriers' inputs: gas_w and oil_w (a boiler's fuel, Hi), heat_w (heat
|
||
bought from a district or the building), dhw_w (hot water's heat drawn,
|
||
where forecast); per hot-water tank its planned temperature
|
||
("tank_c:<id>", °C). Only what the site has (a key absent: not in the plan,
|
||
never 0 for it); the heat outlook (A2.16) adds its fixed heat as drawn."""
|
||
n = min(m.T, FLEX_STEPS)
|
||
out: dict[str, list] = {}
|
||
|
||
def add(key, t, w):
|
||
out.setdefault(key, [0.0] * n)[t] += w
|
||
|
||
for t in range(n):
|
||
add("import_w", t, x(m.gin[t]) + sum((x(v) for v in m.buy[t]), 0.0))
|
||
add("export_w", t, x(m.gout[t]) + sum((x(v) for v in m.sell[t]), 0.0))
|
||
add("load_w", t, max(0.0, float(s["load_w"][t])))
|
||
if any(float(v) > 0 for v in s["pv_w"][:n]):
|
||
out["pv_w"] = [max(0.0, float(v)) for v in s["pv_w"][:n]]
|
||
temps = {}
|
||
for did, (kind, v) in m.devices.items():
|
||
if not v:
|
||
continue
|
||
if kind == "battery":
|
||
for t in range(min(n, len(v["ch"]))):
|
||
add("battery_charge_w", t, _x(x, v["ch"][t]))
|
||
add("battery_discharge_w", t, _x(x, v["dis"][t]))
|
||
continue
|
||
if kind == "ev":
|
||
for t in range(min(n, len(v["power"]))):
|
||
add("ev_w", t, _x(x, v["power"][t]))
|
||
continue
|
||
if kind not in ("heating", "cooling", "dhw_tank"):
|
||
continue
|
||
el = "dhw_element_w" if kind == "dhw_tank" else kind + "_w"
|
||
fuel = (v.get("fuel") or "gas") + "_w"
|
||
for col, key in (("power", el), ("gas", fuel), ("district", "heat_w")):
|
||
xs = v.get(col) or []
|
||
if not any(c is not None and hasattr(c, "index") for c in xs[:n]):
|
||
continue
|
||
for t in range(min(n, len(xs))):
|
||
add(key, t, _x(x, xs[t]))
|
||
if kind == "dhw_tank":
|
||
# its planned mean temperature at each step's end (°C, not W: "tank_c:<id>")
|
||
temps["tank_c:" + did] = [round(tank_temp(v, t, x), 1) for t in range(min(n, len(v["e"])))]
|
||
for t in range(min(n, len(v.get("draw") or []))):
|
||
d = v["draw"][t]
|
||
add("dhw_w", t, float(d) if isinstance(d, (int, float)) else _x(x, d))
|
||
if outlook:
|
||
key = {"gas": "gas_w", "oil": "oil_w", "heat": "heat_w"}.get(outlook.get("carrier"))
|
||
for kind, ln in (outlook.get("lines") or {}).items():
|
||
for t in range(min(n, len(ln["input_w"]))):
|
||
if key:
|
||
add(key, t, float(ln["input_w"][t]))
|
||
if kind == "dhw":
|
||
add("dhw_w", t, float(ln["heat_w"][t]))
|
||
return {**{k: [round(w) for w in v] for k, v in out.items()}, **temps}
|
||
|
||
def _x(x, v) -> float:
|
||
"""A step's value: a variable's, or 0 where there is none (an EV's steps after departure)."""
|
||
return x(v) if v is not None and hasattr(v, "index") else 0.0
|
||
|
||
|
||
def shift_envelope(m, x) -> dict | None:
|
||
"""The energy each controllable device can move over the next 48 h,
|
||
from what the plan already knows (docs/methods.md A11), for the
|
||
building's price bands (building/mieterstrom.py: the flats' agents
|
||
re-plan against the band prices; the building models that response
|
||
with this). Per device, per step (W, Wh; the step is step_s):
|
||
|
||
battery base_w (the planned grid-side power: charge > 0, discharge
|
||
< 0), soc_wh (the state of charge at the start), lo_wh per
|
||
step (its floor: the bounds and the owner's reserve), max_wh
|
||
(its ceiling), cap_wh (its capacity: a metered % in Wh for
|
||
the building's coordinator), ch_w, dis_w (its power), eta (one way), end_wh (the planned
|
||
last state of charge: the building keeps at least it)
|
||
ev, heating, cooling
|
||
base_w (planned), up_w / down_w (the most it can draw above /
|
||
below base_w), lo_wh / hi_wh (the bounds of the moved energy
|
||
store S_t = keep * S_(t-1) + (p_t - base_t) * dt, S_(-1) = 0),
|
||
keep (1 a lossless store: a car; a room's heat decays toward
|
||
its plan: 1 - dt / (R C))
|
||
|
||
Published only from facts: a battery with its ratings (a battery
|
||
without them is not planned at all: U2); a car plugged in whose
|
||
ready-by and energy are the owner's preference or the car's own (never
|
||
the defaults); a room whose R and C are fitted (or the mapping's) with
|
||
the device's COP (the mapping's, or none needed: a fit against the
|
||
electric power) and the owner's band (preferences, or the mapping's
|
||
comfort temperatures); a room without them is not planned at all. None of them: None."""
|
||
s = m.s
|
||
n = min(m.T, SHIFT_STEPS)
|
||
if n <= 0:
|
||
return None
|
||
dt = m.dt
|
||
src = s.get("sources") or {}
|
||
rooms, cops, bands = src.get("rooms") or {}, src.get("rooms_cop") or {}, src.get("rooms_band") or {}
|
||
out = []
|
||
for d in s["devices"]:
|
||
kind, v = m.devices.get(d["id"], (d["kind"], None))
|
||
if v is None:
|
||
continue
|
||
if kind == "battery":
|
||
base = [_x(x, v["ch"][t]) - _x(x, v["dis"][t]) for t in range(n)]
|
||
out.append({"id": d["id"], "kind": "battery", "base_w": [round(b) for b in base],
|
||
"soc_wh": round(v["soc0"]), "lo_wh": [round(v["floors"][t] / 100.0 * v["cap"]) for t in range(n)],
|
||
"max_wh": round(v["hi_wh"]), "cap_wh": round(v["cap"]),
|
||
"ch_w": round(v["max_ch"]), "dis_w": round(v["max_dis"]),
|
||
# where the discharge power came from (mapping | device | owner | ratio: the
|
||
# Parameters row on the one rated power), so the building takes it as the box's
|
||
"dis_src": ((src.get("battery") or {}).get(d["id"]) or {}).get("max_discharge_w"),
|
||
"eta": round(v["eff"], 4), "end_wh": round(_x(x, v["soc"][n - 1])),
|
||
# its idle loss (S.2) and where it came from, for the building's own plan (C2.7)
|
||
"standby_w": round(v.get("p0", 0.0), 1), "loss_pct_h": round(v.get("lam_h", 0.0) * 100.0, 6),
|
||
"standby_src": ((src.get("battery") or {}).get(d["id"]) or {}).get("standby_w", "none")})
|
||
elif kind == "ev":
|
||
if not v.get("known") or v["pmax"] <= 0:
|
||
continue
|
||
p = [_x(x, v["power"][t]) for t in range(n)]
|
||
dep = min(v["dep"], n)
|
||
if dep <= 0 or sum(p) <= 0 and v["need"] <= 0:
|
||
continue
|
||
up = [max(0.0, v["pmax"] - p[t]) if t < dep else 0.0 for t in range(n)]
|
||
down = [p[t] if t < dep else 0.0 for t in range(n)]
|
||
lo, hi, cum = [], [], 0.0
|
||
for t in range(n):
|
||
cum += p[t] * dt
|
||
if t < dep - 1: # before the ready-by: between nothing and the need delivered
|
||
lo.append(-cum)
|
||
hi.append(max(0.0, v["need"] - cum))
|
||
else: # at and after it: what the plan delivers (a ready-by beyond the horizon: no less by its end)
|
||
end = v["need"] - cum
|
||
lo.append(min(0.0, end) if v["dep"] <= n else 0.0)
|
||
hi.append(max(0.0, end))
|
||
out.append({"id": d["id"], "kind": "ev", "base_w": [round(a) for a in p], "up_w": [round(a) for a in up],
|
||
"down_w": [round(a) for a in down], "lo_wh": [round(a) for a in lo], "hi_wh": [round(a) for a in hi],
|
||
"keep": 1.0})
|
||
elif kind in ("heating", "cooling"):
|
||
if v.get("switched"):
|
||
continue # an on/off boiler: all or nothing, not a band of power
|
||
if v.get("src", "electric") not in ("electric", "heat_pump"):
|
||
continue # gas, district heat or a hybrid's choice: no electricity to shift as planned
|
||
if rooms.get(d["id"]) not in ("mapping", "model", "box model", "zone 2r2c") or \
|
||
cops.get(d["id"]) not in ("mapping", "electric fit", "electric heater", "zone fit") or v["wh_per_k"] <= 0:
|
||
continue # no fit or no COP: the heat it can hold is not known
|
||
if not d.get("pref") and bands.get(d["id"]) != "mapping" and not str(bands.get(d["id"]) or "").startswith("en16798"):
|
||
continue # no band of the owner's (or EN 16798-1's, G5)
|
||
p = [_x(x, v["power"][t]) for t in range(n)]
|
||
temps = [_x(x, v["temp"][t]) for t in range(n)]
|
||
k, sign = v["wh_per_k"], (-1.0 if kind == "cooling" else 1.0)
|
||
lo, hi = [], []
|
||
for t in range(n):
|
||
blo, bhi = v["band"][t]
|
||
a, b = sorted((sign * (blo - temps[t]) * k, sign * (bhi - temps[t]) * k))
|
||
lo.append(min(a, 0.0)) # the plan's own temperature is always inside
|
||
hi.append(max(b, 0.0))
|
||
out.append({"id": d["id"], "kind": kind, "base_w": [round(a) for a in p],
|
||
"up_w": [round(max(0.0, v["pmax"] - a)) for a in p], "down_w": [round(a) for a in p],
|
||
"lo_wh": [round(a) for a in lo], "hi_wh": [round(a) for a in hi], "keep": round(v["keep"], 6)})
|
||
elif kind == "dhw_tank":
|
||
if v["heater"] not in ("element", "heat_pump") or v["switched"] or v["pmax"] <= 0:
|
||
continue # gas, district heat or a relay: no band of electric power
|
||
p = [_x(x, v["power"][t]) for t in range(n)]
|
||
cop = sum(v["cops"][:n]) / n
|
||
lo, hi = [], []
|
||
for t in range(n):
|
||
e = _x(x, v["e"][t])
|
||
# the heat it can hold more or less than planned, in Wh of electricity at the mean COP
|
||
lo.append(min(0.0, (v["emin"] - e) / cop))
|
||
hi.append(max(0.0, (v["emax"] - e) / cop))
|
||
out.append({"id": d["id"], "kind": "dhw_tank", "base_w": [round(a) for a in p],
|
||
"up_w": [round(max(0.0, v["pmax"] - a)) for a in p], "down_w": [round(a) for a in p],
|
||
"lo_wh": [round(a) for a in lo], "hi_wh": [round(a) for a in hi], "keep": round(v["phi"], 6)})
|
||
if not out:
|
||
return None
|
||
return {"v": 1, "start": s["start"], "step_s": s["step_s"], "steps": n, "devices": out[:SHIFT_DEVICES]}
|
||
|
||
|
||
def _charge_why(pi, t) -> str:
|
||
"""Why the battery charges from the grid: "cheap grid power" only in the
|
||
cheapest quarter of the horizon's prices and 10 % below their mean
|
||
(sim-munich-1 called 47.6 ct cheap: an evening day-ahead price under a
|
||
50 ct flat); else what it is for, the dearer hours later."""
|
||
p25 = sorted(pi)[len(pi) // 4]
|
||
mean = sum(pi) / len(pi)
|
||
if pi[t] <= p25 + 1e-9 and pi[t] < 0.9 * mean:
|
||
return f"cheap grid power ({pi[t]:.1f} ct)"
|
||
later = pi[t + 1:]
|
||
if later and max(later) > pi[t]:
|
||
k = t + 1 + later.index(max(later))
|
||
return f"charge for dearer hours later ({pi[t]:.1f} ct now, {pi[k]:.1f} ct in {(k - t) * 15 // 60} h)"
|
||
return f"charge from the grid ({pi[t]:.1f} ct)"
|
||
|
||
|
||
def _key(e) -> tuple:
|
||
"""What makes a plan entry a change: a battery's self-consumption is one
|
||
state whatever its power (it follows the house); a hybrid's source."""
|
||
return ("auto",) if e.get("auto") else (e["set"], e.get("grid"), e.get("source"), e.get("dhw_comfort"))
|
||
|
||
|
||
def boiler_fuel(p: dict) -> str:
|
||
"""A boiler's fuel (docs/methods.md E15): "oil" where its control says
|
||
fuel: oil (heating oil EL), else "gas": a boiler before branch
|
||
heating-oil was a gas boiler by definition (the schema's meaning, not a
|
||
guess; inputs.heating_refusal refuses any other fuel)."""
|
||
return "oil" if str((p or {}).get("fuel") or "gas") == "oil" else "gas"
|
||
|
||
|
||
def carrier_costs(s, m, x) -> dict:
|
||
"""What the plan's gas, heating oil and district heat cost (EUR), at
|
||
their prices (the rooms'); a boiler's input (column "gas") at its
|
||
fuel's price."""
|
||
dh = s.get("price_heat") or []
|
||
out = {"gas_eur": 0.0, "heat_eur": 0.0, "oil_eur": 0.0}
|
||
for kind, v in m.devices.values():
|
||
if kind not in ("heating", "dhw_tank") or not v:
|
||
continue
|
||
fuel = v.get("fuel") or "gas"
|
||
for key, prices, col in ((fuel + "_eur", s.get("price_" + fuel) or [], "gas"), ("heat_eur", dh, "district")):
|
||
for t, var in enumerate(v.get(col) or []):
|
||
if var is not None and t < len(prices) and prices[t] is not None:
|
||
out[key] += m.eur_wh(t, prices[t]) * x(var)
|
||
return out
|
||
|
||
|
||
def _inputs_w(v, t, x) -> float:
|
||
"""A heating or cooling device's input in step t (W: electric, gas or
|
||
district heat; a hybrid's both)."""
|
||
return sum(x(c[t]) for c in (v.get("power"), v.get("gas"), v.get("district")) if c and c[t] is not None)
|
||
|
||
|
||
GRID_ZERO_W = 50.0 # the meter's import and export below this: the battery balances the house
|
||
|
||
KEEP_OWN = "release" # executor.RELEASE: the thermostat keeps its own setpoint (nothing written)
|
||
|
||
|
||
def fallback_entries(s, d) -> list[dict]:
|
||
"""A room not planned (inputs.room_refusal): its
|
||
thermostat's fallback schedule, no optimisation. Per step the target of
|
||
the owner's (or installer's) schedule and overrides in force
|
||
(preferences.room_series: a block's temperature, a must at least it;
|
||
outside the blocks the setback (heating) / setup (cooling); a boost;
|
||
away at the setback), rounded to the half degree and held inside the
|
||
room's bounds (the owner's and installer's limits, the device's range).
|
||
Without blocks (an override alone) the steps outside the override keep
|
||
the thermostat's own setpoint (KEEP_OWN). No schedule, or a switched
|
||
heater without a thermostat: none (the executor's safe value: the
|
||
device as it is)."""
|
||
pref = d.get("pref")
|
||
if not pref or "climate" not in (d.get("channels") or []):
|
||
return []
|
||
cooling = d["kind"] == "cooling"
|
||
lo, hi = d["bounds"]["temp_c"][0], d["bounds"]["temp_c"][1]
|
||
lo_h = math.ceil(lo * 2) / 2 if lo is not None else None
|
||
hi_h = math.floor(hi * 2) / 2 if hi is not None else None
|
||
groups = pref["groups"]
|
||
blocks = any(g["kind"] == "block" for g in groups)
|
||
out = []
|
||
for t in range(min(s["steps"], len(pref["target"]))):
|
||
g = pref["group"][t]
|
||
if g == -1 and not blocks:
|
||
e = {"set": KEEP_OWN, "why": "fallback: the thermostat's own setpoint (room not optimised, no schedule)"}
|
||
else:
|
||
want = float(pref["target"][t])
|
||
must = pref["must"][t]
|
||
if must is not None:
|
||
want = min(want, float(must)) if cooling else max(want, float(must))
|
||
v = _round(want, 0.5)
|
||
if lo_h is not None:
|
||
v = max(v, lo_h)
|
||
if hi_h is not None:
|
||
v = min(v, hi_h)
|
||
what = groups[g]["text"] if g >= 0 else ("setup" if cooling else "setback") + " outside your schedule"
|
||
e = {"set": v, "why": f"fallback schedule (room not optimised): {what}"}
|
||
if not out or _key(out[-1]) != _key(e):
|
||
out.append({"t": s["start"] + t * s["step_s"], **e})
|
||
return out
|
||
|
||
|
||
def fallback_feedback(s) -> list[dict]:
|
||
"""A not-planned room's preferences (fallback_entries): not optimised,
|
||
the thermostat set to them; met unknown (no plan of the room to tell)."""
|
||
out = []
|
||
for d in s.get("fallback") or []:
|
||
pref = d.get("pref")
|
||
if not pref or "climate" not in (d.get("channels") or []):
|
||
continue
|
||
for gi, g in enumerate(pref["groups"]):
|
||
out.append({"control": d["id"], "group": g["group"], "kind": g["kind"], "how": g["how"],
|
||
"label": g["text"], "met": None,
|
||
"detail": "room not optimised: set as the thermostat's schedule"
|
||
if gi in pref["group"] else "not in the next 48 h"})
|
||
return out
|
||
|
||
|
||
def _entry(d, kind, v, t, x, s, pi, grid_w=(1e9, 1e9)):
|
||
"""What a device is to do in step t, and why (a few words). grid_w:
|
||
the meter's planned import and export in t."""
|
||
occ = s["occupied"][t]
|
||
if v is None:
|
||
return None
|
||
if kind == "battery":
|
||
net = x(v["ch"][t]) - x(v["dis"][t])
|
||
if 0 < net <= v.get("p0", 0.0) / v["eff"] + 1.0:
|
||
# a charge no larger than the idle loss: the plan holds the battery (at its floor, its
|
||
# standby taken from the grid, as the inverter does itself): no grid charging for it
|
||
net = 0.0
|
||
net = _round(net, 50.0)
|
||
surplus = s["pv_w"][t] - s["load_w"][t]
|
||
grid = net > max(0.0, surplus) + 50
|
||
bld = s.get("building") or {}
|
||
bp, bound = bld.get("battery_plan"), bld.get("battery_bound")
|
||
target = bp["schedule_w"][t] if bp and t < len(bp["schedule_w"]) else None
|
||
if target is not None:
|
||
# the building's plan for its battery (Model.battery_plan): a setpoint, not the own mode
|
||
why = f"building {bp['building']}: its battery plan ({target:+.0f} W)"
|
||
if abs(net - target) > GRID_ZERO_W:
|
||
why += (", more from the PV surplus to your battery's reserve" if bound and net > target and net > 0
|
||
else ", within your battery's limits and reserve")
|
||
return {"set": net, "grid": grid, "why": why}
|
||
if bound:
|
||
# bound to a building without its plan for this step (A9.4): the inverter's own self-consumption
|
||
end = time.strftime("%d %b %H:%M UTC", time.gmtime(bound.get("until") or 0))
|
||
why = (f"building {bound['building']}: its battery plan ended {end}, not renewed" if bound.get("lapsed")
|
||
else f"building {bound['building']}: no battery plan after {end}")
|
||
return {"set": net, "grid": False, "auto": True, "why": why + ": self-consumption only, no grid charging"}
|
||
if not s.get("priced", True):
|
||
# no tariff: the battery in its own mode, unless the owner's
|
||
# reserve needs charging from the grid
|
||
if grid:
|
||
return {"set": net, "grid": True, "why": "charge to the reserve you set (no tariff)"}
|
||
return {"set": net, "grid": False, "auto": True, "why": "no tariff: the battery in its own mode"}
|
||
if net > 0:
|
||
why = _charge_why(pi, t) if grid else "PV surplus"
|
||
elif net < 0:
|
||
mean = sum(pi) / len(pi)
|
||
# "peak" only well above the horizon's average (Sim Munich: a plain
|
||
# 28 ct hour was called a peak)
|
||
why = (f"price peak ({pi[t]:.1f} ct)" if pi[t] >= 1.2 * mean else
|
||
f"above the average price ({pi[t]:.1f} ct, average {mean:.1f})")
|
||
else:
|
||
why = "hold"
|
||
if grid_w[0] < GRID_ZERO_W and grid_w[1] < GRID_ZERO_W and not grid:
|
||
# what the battery does is what its own self-consumption mode does:
|
||
# the inverter follows the house (no setpoint to chase the PV or
|
||
# the load every quarter hour)
|
||
return {"set": net, "grid": False, "auto": True,
|
||
"why": "self-consumption: the battery covers the house" if net <= 0 else
|
||
"self-consumption: PV surplus into the battery"}
|
||
return {"set": net, "grid": grid, "why": why}
|
||
if kind in ("heating", "cooling"):
|
||
e = _room_entry(d, kind, v, t, x, s, pi)
|
||
cc = d.get("dhw_comfort")
|
||
if e is not None and cc and t < len(cc):
|
||
# a combi boiler's comfort mode (G7): on while someone is home and awake, else off
|
||
e["dhw_comfort"] = "on" if cc[t] else "off"
|
||
return e
|
||
if kind == "dhw_tank":
|
||
return _tank_entry(d, v, t, x, s, pi)
|
||
return _entry_rest(d, kind, v, t, x, s, pi)
|
||
|
||
|
||
def _room_entry(d, kind, v, t, x, s, pi):
|
||
"""_entry for a heating or cooling room (its setpoint, a switched boiler's on/off, a hybrid's source)."""
|
||
occ = s["occupied"][t]
|
||
temp = x(v["temp"][t])
|
||
pw = _inputs_w(v, t, x)
|
||
src = v.get("src", "electric")
|
||
# the price that buys the heat now, for the words
|
||
fuel = v.get("fuel") or "gas"
|
||
pr = {"boiler": s.get("price_" + fuel), "district": s.get("price_heat")}.get(src) or pi
|
||
pr_t = pr[t] if t < len(pr) else None
|
||
source = None
|
||
if src == "hybrid":
|
||
hp_w, gas_w = x(v["power"][t]), x(v["gas"][t])
|
||
source = "heat_pump" if hp_w >= gas_w and hp_w > 50 else "boiler" if gas_w > 50 else None
|
||
if source == "boiler":
|
||
pr_t = (s.get("price_" + fuel) or [None] * (t + 1))[t]
|
||
ahead = s["occupied"][min(t + 4, s["steps"] - 1)]
|
||
pref = d.get("pref")
|
||
if pref:
|
||
# a schedule: "someone home" is a target above the setback ahead
|
||
# (below the setup, cooling); its target in place of comfort/setback
|
||
sign = -1 if kind == "cooling" else 1
|
||
tg, k0 = pref["target"], max(t - 1, 0)
|
||
occ = sign * (tg[k0] - pref["base"][k0]) > 0
|
||
ahead = any(sign * (tg[k] - tg[k0]) > 0 for k in range(t, min(t + 4, len(tg))))
|
||
if kind == "heating" and v["switched"] and src != "hybrid":
|
||
on = pw > 0.5 * v["pmax"]
|
||
why = ("pre-heat before someone is home" if on and not occ and ahead else
|
||
"keep the room warm" if on else "off: warm enough or away")
|
||
return {"set": "on" if on else "off", "why": why}
|
||
# the room may dip below a floor in the model (soft, so there is always
|
||
# a plan), but a setpoint never asks for it: clamped into the bounds
|
||
# (the guard would refuse it; the sim's run showed 19.5 under a 20 floor)
|
||
lo, hi = d["bounds"]["temp_c"][0], d["bounds"]["temp_c"][1]
|
||
target = min(max(_round(temp, 0.5), math.ceil(lo * 2) / 2), math.floor(hi * 2) / 2)
|
||
if kind == "cooling":
|
||
if pw < 50:
|
||
return {"set": "off", "why": "off: cool enough or away"}
|
||
return {"set": target, "why": "pre-cool before someone is home" if not occ and ahead else "keep cool"}
|
||
if pw < 50:
|
||
# no heat planned: the thermostat at what the room must keep (the
|
||
# comfort or setback target in the bounds), not at the room's
|
||
# predicted temperature, which a thermostat holds by heating; the
|
||
# room never cooled as planned, every next plan started from it
|
||
# again (a replay of a munich-1 day: kept at 24 °C all evening)
|
||
occ1 = s["occupied"][min(t + 1, s["steps"] - 1)]
|
||
p = d["params"]
|
||
want = float(p["comfort_c"]) if occ1 else float(p["setback_c"])
|
||
if v.get("banded") and t < len(v.get("targets") or []):
|
||
want = float(v["targets"][t]) # the band's edge or the setback (G5)
|
||
occ = bool(v["occ"][t])
|
||
if pref:
|
||
want = float(pref["target"][t])
|
||
if pref["must"][t] is not None:
|
||
want = max(want, float(pref["must"][t]))
|
||
floor_t = min(max(math.floor(want * 2) / 2, math.ceil(lo * 2) / 2), math.floor(hi * 2) / 2)
|
||
return {"set": min(target, floor_t), "why": "setback: away or night" if not occ else "warm enough"}
|
||
what = {"boiler": "heating oil" if fuel == "oil" else "gas", "district": "heat"}.get(
|
||
src if src != "hybrid" else (source or ""), "power")
|
||
e = {"set": target, "why": f"pre-heat while {what} is cheap ({pr_t:.1f} ct)"
|
||
if not occ and ahead and pr_t is not None else "keep the room warm"}
|
||
if source:
|
||
e["source"] = source
|
||
e["why"] += "; " + ("the heat pump: its heat is cheaper now" if source == "heat_pump" else "the boiler: its heat is cheaper now")
|
||
return e
|
||
|
||
|
||
def _entry_rest(d, kind, v, t, x, s, pi):
|
||
"""_entry for an EV and a cover."""
|
||
if kind == "ev":
|
||
if v.get("expected"):
|
||
return None # not plugged in: a forecast load, no command (inputs.ev_session)
|
||
p = v["power"][t]
|
||
if p is None:
|
||
return {"set": "off", "why": "after departure"}
|
||
amps = round(x(p) / v["volts"])
|
||
ph = ((s.get("sources") or {}).get("ev_phases") or {}).get(d["id"])
|
||
ph = f"; {phase_words(ph)}" if ph else ""
|
||
if pi[t] is None:
|
||
if amps < 1:
|
||
return {"set": "off", "why": "not needed now (no tariff)" + ph}
|
||
return {"set": amps, "why": "charge for the departure (no tariff)" + ph}
|
||
if amps < 1:
|
||
return {"set": "off", "why": "wait for cheaper hours" + ph}
|
||
return {"set": amps, "why": f"cheapest hours before departure ({pi[t]:.1f} ct){ph}"}
|
||
if kind == "cover" and v.get("schedule"):
|
||
sch = v["schedule"]
|
||
if sch["set"][t] is None:
|
||
return {"set": None, "why": ""}
|
||
rule = (sch.get("rule") or [""] * (t + 1))[t]
|
||
# the rule it moves for: the executor keeps it for the next plans (shades.Moves)
|
||
return {"set": sch["set"][t], "why": sch["why"][t], **({"rule": rule} if rule else {})}
|
||
if kind == "cover" and v.get("window"):
|
||
# G3: placed by the plan on its window's sun and loss
|
||
w = v["window"]
|
||
pos = _round(100 * x(v["pos"][t]), 10.0)
|
||
if t < w["hold_steps"]:
|
||
return {"set": None, "why": "moved by hand: kept"}
|
||
sun = w["sun_w"][t] if t < len(w["sun_w"]) else 0.0
|
||
if pos < 100 and sun > 50:
|
||
why = "shade: keep the sun's heat out"
|
||
elif sun > 50:
|
||
why = "open: the sun's heat in"
|
||
elif pos < 100 and w["h_sh"] > 0:
|
||
why = "closed: keep the heat in"
|
||
elif pos < 100:
|
||
why = "closed"
|
||
else:
|
||
why = "open"
|
||
return {"set": pos, "why": why}
|
||
if kind == "cover":
|
||
pos = _round(100 * x(v["pos"][t]), 10.0)
|
||
sun = s["sun"][t]
|
||
if pos < 100 and sun > 0.05:
|
||
why = "shade: keep the sun's heat out"
|
||
elif sun > 0.05:
|
||
why = "open: daylight and the sun's heat"
|
||
elif pos < 100:
|
||
why = "closed: no sun"
|
||
else:
|
||
why = "open"
|
||
return {"set": pos, "why": why}
|
||
return None
|
||
|
||
|
||
TANK_HEAT_W = 50.0 # W of heat below which a tank's heater counts as off in a step (ENG: rounding)
|
||
|
||
|
||
def tank_heat(v, t, x) -> float:
|
||
"""A tank's planned heat in step t (W)."""
|
||
return sum(k * x(var) for k, var in v["heat"][t])
|
||
|
||
|
||
def tank_temp(v, t, x) -> float:
|
||
"""A tank's planned mean temperature at the end of step t (S.4 backwards)."""
|
||
return v["t_cw"] + x(v["e"][t]) / v["cw"]
|
||
|
||
|
||
def _tank_entry(d, v, t, x, s, pi):
|
||
"""What a tank's heater is to do in step t (docs/methods.md A13): a
|
||
water heater's target °C (heating: the planned temperature, rounded up
|
||
to the degree; else the comfort's least, which its thermostat keeps), a
|
||
relay's on/off, a stepless element's W, an SG-Ready state (3: store
|
||
above the comfort, 2: normal); and why."""
|
||
q = tank_heat(v, t, x)
|
||
temp = tank_temp(v, t, x)
|
||
on = q > TANK_HEAT_W
|
||
chans = set(d.get("channels") or [])
|
||
lo, hi = v["lo_c"], v["hi_c"]
|
||
leg = v["e_leg"] is not None and t in v["window"] and x(v["e"][t]) >= v["e_leg"] - 1.0
|
||
price = {"boiler": s.get("price_gas"), "district": s.get("price_heat")}.get(v["heater"]) or pi
|
||
pr = price[t] if t < len(price) else None
|
||
if not on:
|
||
why = "off: warm enough"
|
||
elif leg:
|
||
why = f"legionella run ({(v['e_leg'] / v['cw'] + v['t_cw']):.0f} °C)"
|
||
elif v["heater"] in ("element", "heat_pump") and s["pv_w"][t] - s["load_w"][t] > 0.5 * q / max(v["cops"][t], 1.0):
|
||
why = "store PV surplus as hot water"
|
||
elif temp > lo + 1.0 and pr is not None:
|
||
why = f"store heat while it is cheap ({pr:.1f} ct)"
|
||
else:
|
||
why = f"keep the tank at {lo:.0f} °C"
|
||
if "water_heater" in chans:
|
||
target = min(max(math.ceil(temp), math.ceil(lo)), math.floor(hi)) if on else math.ceil(lo)
|
||
return {"set": float(target), "why": why}
|
||
if "power" in chans and v["heater"] in ("element", "heat_pump"):
|
||
return {"set": _round(x(v["power"][t]), 50.0) if on else 0.0, "why": why}
|
||
if "switch" in chans:
|
||
return {"set": "on" if on else "off", "why": why}
|
||
if "sg_ready" in chans:
|
||
return {"set": "sg:3" if on and temp > lo + 1.0 else "sg:2", "why": why}
|
||
return None
|
||
|
||
|
||
def _carrier_price(s, carrier: str, t: int):
|
||
xs = s.get({"electricity": "price_import", "gas": "price_gas", "heat": "price_heat"}[carrier]) or []
|
||
return xs[t] if t < len(xs) else None
|
||
|
||
|
||
def _tank_input_w(v, t, heat_w: float) -> tuple[str, float]:
|
||
"""The carrier and its input (W) for a tank's heat (W): an element's
|
||
electricity, a heat pump's by its COP, a boiler's gas by its full-load
|
||
efficiency, district heat as it is."""
|
||
if v["heater"] in ("element", "heat_pump"):
|
||
return "electricity", heat_w / max(v["cops"][t], 1e-9)
|
||
if v["heater"] == "boiler":
|
||
return "gas", heat_w / (v["eff"] or 1.0)
|
||
return "heat", heat_w
|
||
|
||
|
||
def tank_baseline(m, v) -> float:
|
||
"""The tank without the plan (EUR): its own thermostat holding the
|
||
comfort's least from the same start, the same draw and the standing
|
||
loss, each W of heat at its carrier's mean price over the horizon
|
||
(tank_baseline_steps summed)."""
|
||
return sum(sum(eur) for eur in tank_baseline_steps(m, v).values())
|
||
|
||
|
||
def tank_thermostat_heat(m, v) -> list[float]:
|
||
"""The heat (W per step) the tank's own thermostat gives without the
|
||
plan: from the plan's own start E_0 (the heat in it now), the same
|
||
balance as Model.dhw_tank, E_t = phi E_(t-1) + dt (q_t - D_t - P0),
|
||
heating only when E would fall below the comfort's least E_min, at most
|
||
the heater's output (an element's or heat pump's W x COP, a boiler's or
|
||
heat station's max_heat_w). A tank above its least coasts down as the
|
||
plan's does: the heat already in it is not a saving of the plan (until
|
||
2026-11-09 the baseline held E_min from the first step, and a tank
|
||
started warm showed its stored heat as saved: 0.75 EUR per plan for
|
||
300 L at 55 °C over a 45 °C least, at one price)."""
|
||
return tank_thermostat(m, v)[0]
|
||
|
||
|
||
def tank_thermostat(m, v, emin: float | None = None) -> tuple[list[float], float]:
|
||
"""tank_thermostat_heat holding emin (Wh above the cold water; None:
|
||
the comfort's least E_min): (the heat per step, W; the stored heat at
|
||
the horizon's end, Wh). The store's lever (heatlevers.py) holds the
|
||
store's own setpoint with it."""
|
||
e, dt, out = v["e0"], m.dt, []
|
||
emin = v["emin"] if emin is None else emin
|
||
for t in range(m.T):
|
||
need = (emin - v["phi"] * e) / dt + v["draw"][t] + v["p0"]
|
||
if v["heater"] in ("element", "heat_pump"):
|
||
cap = v["pmax"] * v["cops"][t] if v["pmax"] else math.inf
|
||
else:
|
||
cap = v.get("qmax") or math.inf
|
||
q = min(max(0.0, need), cap)
|
||
e = v["phi"] * e + dt * (q - v["draw"][t] - v["p0"])
|
||
out.append(q)
|
||
return out, e
|
||
|
||
|
||
def tank_baseline_steps(m, v) -> dict:
|
||
"""tank_baseline per carrier and step: {carrier: [EUR per step]}, the
|
||
carriers with a price only (step_costs' base side, so the split's base
|
||
is baseline()): the thermostat's heat (tank_thermostat_heat) as its
|
||
heater's input at the carrier's mean price."""
|
||
s = m.s
|
||
out = {}
|
||
heat = tank_thermostat_heat(m, v)
|
||
for carrier in ("electricity", "gas", "heat"):
|
||
ps = [p for p in [_carrier_price(s, carrier, t) for t in range(m.T)] if p is not None]
|
||
if not ps:
|
||
continue
|
||
mean = sum(ps) / len(ps)
|
||
eur = [0.0] * m.T
|
||
for t in range(m.T):
|
||
c, w = _tank_input_w(v, t, heat[t])
|
||
if c == carrier:
|
||
eur[t] += m.eur_wh(t, mean) * w
|
||
out[carrier] = eur
|
||
return out
|
||
|
||
|
||
def storage_report(s, m, x) -> dict:
|
||
"""Per store what it loses while it holds energy (design note 10.5):
|
||
the battery's idle loss (its standby and the cells' self-discharge,
|
||
S.2) and the tank's standing loss (S.5), over the horizon and its first
|
||
24 h, each kWh at the step's price of what replaces it (the import
|
||
price; a tank's heat by its carrier); the facts with their source; a
|
||
tank's planned temperatures and heat per hour, its draw, the comfort it
|
||
missed and its legionella run."""
|
||
out = {}
|
||
src = s.get("sources") or {}
|
||
n24 = min(m.T, FLEX_STEPS)
|
||
for d in s["devices"]:
|
||
kind, v = m.devices.get(d["id"], (d["kind"], None))
|
||
if v is None or kind not in ("battery", "dhw_tank"):
|
||
continue
|
||
if kind == "battery":
|
||
loss = []
|
||
for t in range(m.T):
|
||
prev = x(v["soc"][t - 1]) if t else v["soc0"]
|
||
loss.append((1.0 - v["phi"]) * prev + m.dt * v["p0"]) # Wh in the step
|
||
fsrc = (src.get("battery") or {}).get(d["id"]) or {}
|
||
eur = sum(loss[t] / 1000.0 * (s["price_import"][t] or 0.0) / 100.0 for t in range(n24)) if m.priced else None
|
||
r = {"kind": "battery", "standby_w": round(v["p0"], 1), "standby_src": fsrc.get("standby_w", "none"),
|
||
"self_discharge_pct_month": round(v["lam_h"] * HOURS_PER_MONTH * 100.0, 3),
|
||
"self_discharge_src": fsrc.get("self_discharge_pct_month", "none"), "standby_in_load": v["in_load"],
|
||
"idle_loss_kwh": round(sum(loss) / 1000.0, 3), "idle_loss_kwh_24h": round(sum(loss[:n24]) / 1000.0, 3),
|
||
"idle_loss_eur_24h": None if eur is None else round(eur, 3),
|
||
"from_grid_kwh": round(sum(m.dt * x(g) for g in v["lg"]) / 1000.0, 3)}
|
||
fit = (src.get("battery_fit") or {}).get(d["id"])
|
||
if fit:
|
||
r["fit"] = fit
|
||
if r["from_grid_kwh"] > 0.001 and v["in_load"] is None:
|
||
m.note(f"{d['id']}: the battery's standby drawn from the grid at times; whether the house load holds "
|
||
"it is not said (mapping standby_in_load): not added to the load")
|
||
out[d["id"]] = r
|
||
continue
|
||
p, st = d["params"], d["state"]
|
||
loss, eur = [], 0.0
|
||
for t in range(m.T):
|
||
prev = x(v["e"][t - 1]) if t else v["e0"]
|
||
lw = v["ua"] * (v["t_cw"] + prev / v["cw"] - v["room"]) # W, UA (T - T_room)
|
||
loss.append(lw * m.dt)
|
||
if t < n24 and m.priced:
|
||
c, w = _tank_input_w(v, t, max(0.0, lw))
|
||
pr = _carrier_price(s, c, t)
|
||
eur += m.eur_wh(t, pr) * w if pr is not None else 0.0
|
||
heat = [tank_heat(v, t, x) for t in range(m.T)]
|
||
temps = [tank_temp(v, t, x) for t in range(m.T)]
|
||
hours = range(0, m.T, 4)
|
||
r = {"kind": "dhw_tank", "heater": v["heater"], "volume_l": float(p["volume_l"]), "ua_w_k": round(v["ua"], 3),
|
||
"standby_w": round(v["ua"] * ERP_TEST_DT_K, 1), "loss_src": ((src.get("dhw_tank") or {}).get(d["id"]) or {}).get(
|
||
"ua_w_k", "none"),
|
||
"temp_c": round(float(st["temp_c"]), 1), "stored_kwh": round(v["e0"] / 1000.0, 2),
|
||
"usable_kwh": round(max(0.0, v["e0"] - v["emin"]) / 1000.0, 2), "min_temp_c": round(v["lo_c"], 1),
|
||
"max_temp_c": round(v["hi_c"], 1), "grossanlage": bool(p.get("grossanlage")),
|
||
# its cold water and room (°C): the building plan composes a central boiler's store with them (C2.12)
|
||
"room_c": round(float(v["room"]), 1), "cold_water_c": round(float(v["t_cw"]), 1),
|
||
"idle_loss_kwh": round(sum(loss) / 1000.0, 3), "idle_loss_kwh_24h": round(sum(loss[:n24]) / 1000.0, 3),
|
||
"idle_loss_eur_24h": round(eur, 3) if m.priced else None,
|
||
"draw_kwh_24h": round(sum(v["draw"][:n24]) * m.dt / 1000.0, 3),
|
||
"heat_kwh_24h": round(sum(heat[:n24]) * m.dt / 1000.0, 3),
|
||
"short_kwh": round(sum(x(u) for u in v["unmet"]) * m.dt / 1000.0, 3),
|
||
"temp_plan_c": [round(temps[min(k + 3, m.T - 1)], 1) for k in hours],
|
||
"heat_w": [round(sum(heat[k:k + 4]) / len(heat[k:k + 4])) for k in hours],
|
||
"legionella": {"mode": str(p.get("legionella") or "device"), "last": (st.get("legionella") or {}).get("last"),
|
||
"due": (st.get("legionella") or {}).get("due"), "planned": None}}
|
||
if p.get("erp_class"):
|
||
r["erp_class"] = p["erp_class"]
|
||
if v["e_leg"] is not None:
|
||
hit = next((t for t in v["window"] if x(v["e"][t]) >= v["e_leg"] - 1.0), None)
|
||
r["legionella"]["planned"] = s["start"] + (hit + 1) * s["step_s"] if hit is not None else None
|
||
if r["short_kwh"] > 0.05:
|
||
m.note(f"{d['id']}: the tank cannot give {r['short_kwh']:.1f} kWh of the hot water forecast "
|
||
"(its heater's power or maximum temperature)")
|
||
out[d["id"]] = r
|
||
return out
|
||
|
||
|
||
def heat_outlook(s, m) -> dict | None:
|
||
"""The heat no model in the plan decides (docs/methods.md A2.16;
|
||
backlog 45.3, the box's part): the site's space heat where no room
|
||
model plans it (every heating control refused, or none) and its hot
|
||
water (an unshiftable demand today; a tank between it and its heater:
|
||
backlog 329), each a heat_demand delivered when demanded by the site's
|
||
source (state["heat_site"], inputs.heat_site: a boiler's gas by its
|
||
efficiency at the load, E6.4; district heat as it is), at the carrier's
|
||
price and CO2. A fixed term of the plan's cost (nothing in it is
|
||
decided). {source, from, carrier, eur, co2_kg, heat_kwh, input_kwh,
|
||
efficiency, part_load, lines: {space, dhw: HeatSupply.delivered}}; None
|
||
where none can be made (the reason noted, quietly: a control's refusal
|
||
says what to enter; no hot-water meter is nobody's fault)."""
|
||
site = s.get("heat_site") or {}
|
||
if site.get("note"):
|
||
m.note(site["note"])
|
||
return None
|
||
src = site.get("source")
|
||
if src not in ("boiler", "district"):
|
||
return None
|
||
if src == "boiler" and not site.get("boiler_efficiency"):
|
||
m.note("heat outlook: the boiler's efficiency unknown")
|
||
return None
|
||
sup = HeatSupply(m, site.get("from") or "heat", site, src)
|
||
if not any(p is not None for p in sup.prices[:m.T]):
|
||
m.note(f"heat outlook: no {sup.carrier} price")
|
||
return None
|
||
lines = {}
|
||
# hot water a planned tank stores and heats is the tank's (Model.dhw_tank): not here again
|
||
tanked = any(k == "dhw_tank" and v for k, v in m.devices.values())
|
||
for kind in (("space",) if site.get("space") else ()) + (() if tanked else ("dhw",)):
|
||
q = heat_demand(s, kind, m.T)
|
||
if q is None:
|
||
m.note("heat outlook: no heat forecast for this site" if kind == "space" else
|
||
"heat outlook: no hot-water forecast (no hot-water meter at this site yet): hot water not in it")
|
||
continue
|
||
lines[kind] = sup.delivered(q)
|
||
if not lines:
|
||
return None
|
||
co2 = [ln["co2_kg"] for ln in lines.values()]
|
||
out = {"source": src, "from": site.get("from", ""), "carrier": sup.carrier,
|
||
"eur": round(sum(ln["eur"] for ln in lines.values()), 2),
|
||
"co2_kg": None if None in co2 else round(sum(co2), 2),
|
||
"heat_kwh": round(sum(ln["heat_kwh"] for ln in lines.values()), 2),
|
||
"input_kwh": round(sum(ln["input_kwh"] for ln in lines.values()), 2), "lines": lines}
|
||
unpriced = sum(ln.get("unpriced_kwh", 0.0) for ln in lines.values())
|
||
if unpriced:
|
||
out["unpriced_kwh"] = round(unpriced, 2)
|
||
if src == "boiler":
|
||
out["efficiency"] = sup.eff
|
||
out["part_load"] = sup.curve["from"]
|
||
if is_combi(site) and "dhw" in lines:
|
||
# a combi (392): its hot water, as drawn or into its store (E6.6)
|
||
out["combi"] = True
|
||
return out
|
||
|
||
|
||
def co2_report(s, m, x, outlook) -> dict | None:
|
||
"""The plan's CO2 (kg) by carrier, and the baseline's (A2.15): the
|
||
meter's import at each step's factor (feed-in earns no credit), the
|
||
rooms' gas and district heat at theirs, the heat outlook's;
|
||
the baseline as baseline() (the house's net import without a battery,
|
||
the devices' electricity at the horizon's mean factor, the same gas and
|
||
heat). Steps or carriers without a factor are left out (incomplete:
|
||
true). None where the bundle has no CO2 factor at all."""
|
||
c = s.get("co2") or {}
|
||
if not c:
|
||
return None
|
||
T = m.T
|
||
kwh = m.dt / 1000.0
|
||
out, base, incomplete = {"electricity": 0.0}, {"electricity": 0.0}, False
|
||
fe = [m.co2_factor("electricity", t) for t in range(T)]
|
||
known = [f for f in fe if f is not None]
|
||
mean = sum(known) / len(known) if known else None
|
||
for t in range(T):
|
||
if fe[t] is None:
|
||
incomplete = True
|
||
continue
|
||
out["electricity"] += x(m.gin[t]) * kwh * fe[t] / 1000.0
|
||
net = s["load_w"][t] - s["pv_w"][t]
|
||
base["electricity"] += max(net, 0.0) * kwh * fe[t] / 1000.0
|
||
for kind, v in m.devices.values():
|
||
if not v or kind not in ("heating", "cooling", "ev", "dhw_tank"):
|
||
continue
|
||
if mean is not None:
|
||
base["electricity"] += sum(x(p) * kwh * mean / 1000.0 for p in v.get("power") or [] if p is not None
|
||
and hasattr(p, "index"))
|
||
for col, carrier in (("gas", v.get("fuel") or "gas"), ("district", "heat")):
|
||
e = sum(x(g) * kwh for g in v.get(col) or [] if g is not None)
|
||
if e <= 0:
|
||
continue
|
||
f = m.co2_factor(carrier, 0)
|
||
if f is None:
|
||
incomplete = True
|
||
continue
|
||
out[carrier] = out.get(carrier, 0.0) + e * f / 1000.0
|
||
base[carrier] = base.get(carrier, 0.0) + e * f / 1000.0
|
||
if outlook is not None:
|
||
if outlook.get("co2_kg") is None:
|
||
incomplete = True
|
||
else:
|
||
out[outlook["carrier"]] = out.get(outlook["carrier"], 0.0) + outlook["co2_kg"]
|
||
base[outlook["carrier"]] = base.get(outlook["carrier"], 0.0) + outlook["co2_kg"]
|
||
r = {"plan": round(sum(out.values()), 2), "baseline": round(sum(base.values()), 2),
|
||
"carriers": {k: round(v, 2) for k, v in out.items()}}
|
||
if incomplete:
|
||
r["incomplete"] = True
|
||
if m.co2w:
|
||
r["weight_eur_per_t"] = m.co2w
|
||
if c.get("electricity_source"):
|
||
r["electricity_source"] = c["electricity_source"]
|
||
return r
|
||
|
||
|
||
def baseline(s, m, x) -> float:
|
||
"""An estimate of the cost without the plan: the house's net load at its
|
||
prices, no battery, and the devices' energy (as the plan uses it) at the
|
||
mean import price, the EV's as soon as it is plugged in; None without
|
||
a tariff."""
|
||
if not m.priced:
|
||
return None
|
||
T, pi, pe = m.T, s["price_import"], s["price_export"]
|
||
cost = 0.0
|
||
for t in range(T):
|
||
net = s["load_w"][t] - s["pv_w"][t]
|
||
cost += m.eur_wh(t, pi[t]) * max(net, 0) - m.eur_wh(t, pe[t]) * max(-net, 0)
|
||
mean = sum(pi) / T
|
||
for kind, v in m.devices.values():
|
||
if not v:
|
||
continue
|
||
if kind == "battery":
|
||
# its idle loss is there with or without the plan: replaced at the mean import price (S.2)
|
||
cost += sum(m.eur_wh(t, mean) for t in range(T)) * v.get("p0", 0.0)
|
||
elif kind == "dhw_tank":
|
||
cost += tank_baseline(m, v)
|
||
if kind in ("heating", "cooling"):
|
||
# each input as the plan uses it at its mean price (electricity, gas, district heat)
|
||
cost += sum(m.eur_wh(t, mean) * x(v["power"][t]) for t in range(T) if v["power"][t] is not None)
|
||
for col, key in (("gas", "price_" + (v.get("fuel") or "gas")), ("district", "price_heat")):
|
||
ps = [p for p in (s.get(key) or [])[:T] if p is not None]
|
||
if ps and any(c is not None for c in v.get(col) or []):
|
||
mp = sum(ps) / len(ps)
|
||
cost += sum(m.eur_wh(t, mp) * x(c) for t, c in enumerate(v[col]) if c is not None)
|
||
elif kind == "ev":
|
||
wh = sum(m.dt * x(p) for p in v["power"] if p is not None)
|
||
# as soon as it can charge: from now, an expected session from its arrival
|
||
a = next((t for t, p in enumerate(v["power"]) if p is not None), 0)
|
||
asap = pi[a:a + max(1, math.ceil(wh / max(1.0, v["volts"] * 16) / m.dt))] or pi[:1]
|
||
cost += wh / 1000.0 * (sum(asap) / len(asap)) / 100.0
|
||
return cost
|
||
|
||
|
||
def step_costs(s, m, x) -> dict | None:
|
||
"""Per step and carrier what the plan costs and what the same step
|
||
would cost without it, at the same prices (EUR; costs.py books the step
|
||
of each quarter-hour as the household's saving by the plan, methods.md
|
||
A12):
|
||
electricity plan: the grid's import less its feed-in at the step's
|
||
prices, and the market's contracts in the step (a
|
||
tenant-power flat's energy bought from its building at the
|
||
offer's price of that slot, a sale at its price; as
|
||
energy_of, market_plan); without: the house's net load at
|
||
the grid's prices (no battery) and the planned devices'
|
||
electric energy of the step at the horizon's mean import
|
||
price (a car's at the mean of its as-soon-as-possible
|
||
steps, a tank's by its own thermostat), as baseline()
|
||
gas, heat the heating's gas or district heat of the step at its
|
||
price, against the same energy at the horizon's mean price
|
||
(a tank's: its own thermostat's, tank_baseline_steps)
|
||
Summed over the steps and carriers, plan is cost_eur and base
|
||
baseline_eur, each less the heat outlook (a fixed term in both): the
|
||
split's saving is the plan's own. A step's saving can be
|
||
negative (a battery charging now for later). None without a tariff."""
|
||
if not m.priced:
|
||
return None
|
||
T, pi, pe = m.T, s["price_import"], s["price_export"]
|
||
el_plan = [m.eur_wh(t, pi[t]) * x(m.gin[t]) - m.eur_wh(t, pe[t]) * x(m.gout[t]) for t in range(T)]
|
||
for c, vars_, paid_ in getattr(m, "contracts", []):
|
||
for t, e, pay, price in contract_energy(m, x, c, vars_, paid_):
|
||
el_plan[t] += contract_eur(c, e, pay, price)
|
||
tanks = {d: tank_baseline_steps(m, v) for d, (kind, v) in m.devices.items() if kind == "dhw_tank" and v}
|
||
el_base = []
|
||
for t in range(T):
|
||
net = s["load_w"][t] - s["pv_w"][t]
|
||
el_base.append(m.eur_wh(t, pi[t]) * max(net, 0) - m.eur_wh(t, pe[t]) * max(-net, 0))
|
||
mean = sum(pi) / T
|
||
out = {"electricity": {"plan": el_plan, "base": el_base}}
|
||
for carrier, col, key in (("gas", "gas", "price_gas"), ("oil", "gas", "price_oil"), ("heat", "district", "price_heat")):
|
||
prices = (s.get(key) or [])[:T]
|
||
ps = [p for p in prices if p is not None]
|
||
if not ps:
|
||
continue
|
||
mp = sum(ps) / len(ps)
|
||
plan_c, base_c, used = [0.0] * T, [0.0] * T, False
|
||
for d, (kind, v) in m.devices.items():
|
||
if kind not in ("heating", "dhw_tank") or not v:
|
||
continue
|
||
if col == "gas" and (v.get("fuel") or "gas") != carrier:
|
||
continue # a boiler's input at its own fuel's price only
|
||
for t, var in enumerate(v.get(col) or []):
|
||
if var is not None and t < len(prices) and prices[t] is not None:
|
||
used = True
|
||
plan_c[t] += m.eur_wh(t, prices[t]) * x(var)
|
||
if kind == "heating":
|
||
base_c[t] += m.eur_wh(t, mp) * x(var)
|
||
if kind == "dhw_tank" and carrier in tanks[d]:
|
||
# without the plan: the tank's own thermostat (baseline's tank_baseline)
|
||
used = used or any(tanks[d][carrier])
|
||
for t, eur in enumerate(tanks[d][carrier]):
|
||
base_c[t] += eur
|
||
if used:
|
||
out[carrier] = {"plan": plan_c, "base": base_c}
|
||
for d, (kind, v) in m.devices.items():
|
||
if not v:
|
||
continue
|
||
if kind == "battery" and v.get("p0"):
|
||
for t in range(T):
|
||
el_base[t] += m.eur_wh(t, mean) * v["p0"]
|
||
if kind in ("heating", "cooling"):
|
||
for t in range(T):
|
||
if v["power"][t] is not None:
|
||
el_base[t] += m.eur_wh(t, mean) * x(v["power"][t])
|
||
elif kind == "dhw_tank":
|
||
for t, eur in enumerate(tanks[d].get("electricity") or []):
|
||
el_base[t] += eur
|
||
elif kind == "ev":
|
||
wh = sum(m.dt * x(p) for p in v["power"] if p is not None)
|
||
# as soon as it can charge: from now, an expected session from its arrival
|
||
a = next((t for t, p in enumerate(v["power"]) if p is not None), 0)
|
||
asap = pi[a:a + max(1, math.ceil(wh / max(1.0, v["volts"] * 16) / m.dt))] or pi[:1]
|
||
amean = sum(asap) / len(asap)
|
||
for t, p in enumerate(v["power"]):
|
||
if p is not None:
|
||
el_base[t] += m.eur_wh(t, amean) * x(p)
|
||
return {c: {k: [round(y, 5) for y in ys] for k, ys in d.items()} for c, d in out.items()}
|
||
|
||
|
||
def main():
|
||
s = json.load(sys.stdin)
|
||
limit = float(sys.argv[1]) if len(sys.argv) > 1 else 30.0
|
||
try:
|
||
out = plan(s, limit)
|
||
except Exception as e: # the caller keeps its last plan
|
||
json.dump({"v": 1, "error": str(e)}, sys.stdout)
|
||
sys.exit(1)
|
||
json.dump(out, sys.stdout)
|
||
|
||
|
||
if __name__ == "__main__":
|
||
main()
|