// Copyright © 2026 Setti Solutions S.R.L, www.setti.md. All rights reserved. package main import "time" // The values the bridge uses that are not facts of a device (docs/ // parameters.md U3, E9: no number standing for a real-world fact lives in // the code unless it is law, a specification's rule or a safe side). One // place: every use refers to these. // Para14aMinW: §14a EnWG's minimum power a grid operator must leave a // controllable consumer (Mindestbezugsleistung, 4.2 kW): Bundesnetzagentur, // Festlegung BK6-22-300 of 27.11.2023, Anlage 1 (netzorientierte Steuerung). // Used only as the LPC failsafe limit the bridge holds until the control box // writes its own (the lowest the operator may impose: the safe side); the // control box's own value wins as soon as it sent one. Not applied: the // higher minimum for several devices or large heat pumps behind one energy // manager (Anlage 1's scaling): the control box computes the limit. const Para14aMinW = 4200.0 // LPCFailsafeDurationMin: the shortest failsafe duration the EEBUS use case // allows (UC TS Limitation of Power Consumption V1.0.0, scenario 2: the // failsafe duration minimum is 2 h to 24 h; eebus-go's cs/lpc // SetFailsafeDurationMinimum refuses anything outside). Held until the // control box writes its own. const LPCFailsafeDurationMin = 2 * time.Hour // OrderPhases: a W budget turned into amps for a wallbox whose phase count // is not known: three phases, the most a connection has, so the current // never lets it draw more than the budget (the safe side, as the agent's // evphases.ASSUMED["order"]). Never used to declare a power. const OrderPhases = 3.0 // IECMinChargeA: the least charging current a wallbox can signal (IEC // 61851-1, control pilot PWM: 6 A); below it a wallbox's share pauses it. // The wallbox's own current_min wins where it reports one. const IECMinChargeA = 6.0