@@ -49,8 +49,23 @@ lifts its limit, and it can't be unpaired on the page (only the grid
|
||||
operator, through Cantabile). While it limits the home, the add-on passes
|
||||
the limit on to the heat pumps and wallboxes at once and the Cantabile
|
||||
agent plans within it. Without the control box's heartbeat for two
|
||||
minutes the failsafe limit holds (4.2 kW unless the control box set
|
||||
another) for its failsafe time.
|
||||
minutes the failsafe limit holds for its failsafe time: the control box's
|
||||
own values; until it sent them §14a's minimum of 4.2 kW (BNetzA
|
||||
BK6-22-300) for the shortest time the EEBUS use case allows (2 hours).
|
||||
|
||||
Toward the control box the add-on declares the controllable devices'
|
||||
nominal power: what the heat pumps and wallboxes report (a heat pump's
|
||||
nominal power, a wallbox's maximum current and phases), else the rating
|
||||
you enter on a device's page (from its nameplate). It never declares a
|
||||
guess: while any heat pump or wallbox has no known power, or none is
|
||||
paired, nothing is declared and the add-on does not offer the grid
|
||||
operator's use case (LPC); the page's grid card says why ("nominal power
|
||||
unknown: enter the controllable devices' ratings") and which device needs
|
||||
a rating. When a limit ends, a wallbox goes back to its own maximum
|
||||
current, else to the current it had before; if neither is known it stays
|
||||
and the page says so. While its power is not known, a device's share of a
|
||||
limit is an equal one (the sum never exceeds the limit), and a W budget is
|
||||
turned into amps as if on three phases (never more than the budget).
|
||||
|
||||